Diploma in Active/Passive Filters and Compensation

Online postgraduate diploma of 800 hours in active and passive filters and compensation. 8 modules covering reactive power compensation, passive filters, active power filters, static compensators, filtering solution design, converter control for compensation and installation, commissioning and maintenance, with an assigned technical tutor.

Duration6–8 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Size reactive power compensation systems.

02

Design single-tuned, detuned and high-pass passive filters.

03

Explain how active power filters work and how they are controlled.

04

Compare SVC, STATCOM, DVR and UPQC static compensators.

05

Select the filtering solution through impedance studies.

06

Implement resonant and repetitive controllers for compensation.

07

Commission and maintain filtering and compensation equipment.

Profile

Who it's for

  • Power quality engineers.
  • Reactive power compensation engineers.
  • Power electronics engineers working on grid-connected converters.
  • Electrical project engineers.
  • Commissioning technicians for compensation and filtering equipment.
  • Energy consultants advising industrial clients.
  • Engineering or science graduates aiming to enter industry.
Standards & tools

What you'll work with

  • IEC 60831-1 (shunt power capacitors of the self-healing type for AC systems up to 1 kV)
  • IEC 61642 (industrial AC networks affected by harmonics — application of filters and shunt capacitors)
  • IEEE 1531-2020 (guide for the application and specification of harmonic filters)
  • IEEE 519-2022 (harmonic control in electric power systems)
  • IEC 62927 (voltage sourced converter valves for static synchronous compensators)
  • IEEE 18-2012 (shunt power capacitors)
  • IEC 61000-2-4 (compatibility levels in industrial plants for low-frequency conducted disturbances)
  • IEC 60871-1 (shunt capacitors for AC power systems above 1 kV)
  • DIgSILENT PowerFactory
  • ETAP
  • PSCAD
  • MATLAB/Simulink with Simscape Electrical
  • PLECS
Syllabus

8 modules

  1. 1.1Reactive power and power factor
  2. 1.2Penalties and tariffs for reactive energy
  3. 1.3Fixed and automatic capacitor banks
  4. 1.4Power factor controllers
  5. 1.5Switching with contactors and thyristors
  6. 1.6Sizing the compensation
  7. 1.7Individual, group and central compensation
  8. 1.8Overcompensation and its risks
  9. 1.9Capacitors according to IEC 60831
  10. 1.10Practical exercise: sizing an automatic capacitor bank
  1. 2.1Single-tuned filters
  2. 2.2Detuned filters with blocking reactors
  3. 2.3Detuning factor and selection of p
  4. 2.4Second- and third-order high-pass filters
  5. 2.5C-type filters
  6. 2.6Design of multi-branch filters
  7. 2.7Thermal and voltage rating
  8. 2.8Ageing and detuning due to tolerances
  9. 2.9Interaction with the network impedance
  10. 2.10Workshop: design of a 7% detuned filter
  1. 3.1Principle of the shunt active filter
  2. 3.2Series active filter
  3. 3.3Hybrid active-passive filters
  4. 3.4Inverter topologies for active filters
  5. 3.5Instantaneous p-q power theory
  6. 3.6Synchronous reference frame method
  7. 3.7Hysteresis and predictive current control
  8. 3.8Sizing in compensation amperes
  9. 3.9Bandwidth limitations
  10. 3.10Lab: simulation of a shunt active filter
  1. 4.1Static var compensator (SVC)
  2. 4.2Thyristor-controlled reactors
  3. 4.3STATCOM and its control
  4. 4.4Dynamic voltage restorer for dips (DVR)
  5. 4.5Unified power quality conditioner (UPQC)
  6. 4.6Unbalance compensation
  7. 4.7Flicker compensation in arc furnaces
  8. 4.8Low- and medium-voltage equipment
  9. 4.9Comparison of performance and costs
  10. 4.10Case study: STATCOM for a wind farm
  1. 5.1Load and spectrum characterisation
  2. 5.2Modelling the network and the installation
  3. 5.3Impedance scans and resonances
  4. 5.4Choosing between passive and active filters
  5. 5.5Coordination with protection
  6. 5.6Optimal location of filters
  7. 5.7Parametric sensitivity studies
  8. 5.8Technical specifications for procurement
  9. 5.9Life-cycle cost analysis
  10. 5.10Practical exercise: filtering study in PowerFactory
  1. 6.1Real-time harmonic detection
  2. 6.2PLL and grid synchronisation
  3. 6.3Proportional-resonant controllers
  4. 6.4Repetitive control for periodic harmonics
  5. 6.5Selective harmonic compensation
  6. 6.6DC bus control
  7. 6.7Implementation on a DSP
  8. 6.8Stability with weak grids
  9. 6.9HIL validation
  10. 6.10Lab: resonant control of an active filter
  1. 7.1Protection of capacitor banks and filters
  2. 7.2Commissioning tests
  3. 7.3Verifying filtering effectiveness
  4. 7.4Predictive maintenance of capacitors
  5. 7.5Thermography of compensation equipment
  6. 7.6Remote monitoring of filters
  7. 7.7Safety when working with capacitors
  8. 7.8Alarm and fault management
  9. 7.9Final verification report
  10. 7.10Case study: commissioning an active filter
  1. 8.1Analysis of the existing installation
  2. 8.2Load measurement and characterisation
  3. 8.3Resonance study
  4. 8.4Design of the compensation solution
  5. 8.5Design of passive or active filters
  6. 8.6Simulation of the proposed solution
  7. 8.7Economic assessment and payback
  8. 8.8Commissioning plan
  9. 8.9Report and presentation
  10. 8.10Final project: final review with your tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within each intake, so you can combine it with your job.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIgSILENT PowerFactory, ETAP, PSCAD, MATLAB/Simulink with Simscape Electrical and PLECS, in free, academic or evaluation versions. Testing is studied through real procedures for sizing capacitor banks in industrial installations, resonance studies prior to filter installation and verification of active filters after commissioning. Assessment is continuous by module, plus the final project.

Standards covered: IEC 60831-1, IEC 61642, IEEE 1531-2020, IEEE 519-2022, IEC 62927, IEEE 18-2012, IEC 61000-2-4, IEC 60871-1.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of IEC 60831-1, IEC 61642 and IEEE 1531-2020 applied to real cases, not as a theoretical annex.
Industry software:DIgSILENT PowerFactory, ETAP, PSCAD, MATLAB/Simulink with Simscape Electrical and PLECS, in free, academic or evaluation versions.
Final project:a complete filtering and compensation solution for an existing installation, from load measurement and resonance study to filter design, simulation, economic assessment and commissioning plan, reviewed by your tutor.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Installation analysis
Analyse the existing installation and measure and characterise its loads.
Resonance study
Carry out the impedance scan and resonance study of the network.
Compensation and filter design
Design the compensation solution and the passive or active filters.
Simulation and economics
Simulate the proposed solution and assess its cost and payback.
Final project
Present the documented project with its commissioning plan to your tutor.
Career opportunities

Where this takes you

Power quality engineerReactive power compensation engineerPower electronics engineerElectrical project engineerCommissioning technicianEnergy consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours over 6–8 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with DIgSILENT PowerFactory, ETAP, PSCAD, MATLAB/Simulink with Simscape Electrical and PLECS, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.

Prior technical training or professional experience in the sector (no university degree required), a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Diploma in Active/Passive Filters and CompensationEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.