Road Photometry and Lighting Safety Course
Online course of 300 hours in road photometry and lighting safety: 6 modules covering UNE-EN 13201-2, UNE-EN 13201-3 and UNE-EN 13201-4 applied to real cases, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Understand the visual mechanisms involved in night-time driving.
Select lighting classes in accordance with the UNE-EN 13201 series.
Carry out photometric calculations of luminance, illuminance and glare.
Measure and verify installations in the field according to UNE-EN 13201-4.
Solve special cases such as tunnels, roundabouts and pedestrian crossings.
Relate photometric parameters to road safety.
Develop a complete road photometry project for an urban road section.
Who it's for
- Lighting engineers.
- Public lighting technicians.
- Road safety auditors assessing night-time conditions.
- Photometric laboratory technicians.
- Electrical installation designers.
- Urban lighting consultants.
- Engineering or science graduates looking to move into local government.
What you'll work with
- UNE-EN 13201-2 (road lighting performance requirements)
- UNE-EN 13201-3 (calculation of road lighting performance)
- UNE-EN 13201-4 (methods of measuring lighting performance)
- CEN/TR 13201-1 (guidelines on selection of lighting classes)
- Royal Decree 1890/2008 (ITC-EA-02) (Spanish lighting level requirements for outdoor installations)
- CIE 140:2019 (road lighting calculations)
- CIE 88:2004 (lighting of road tunnels and underpasses)
- UNE-EN 13032-1 (measurement and presentation of photometric data of lamps and luminaires)
- DIALux evo
- Relux
- LITESTAR 4D
- LMK LabSoft
- Eulumdat Tools
6 modules
1.1Physiology of photopic, mesopic and scotopic vision1.2Contrast, threshold and obstacle detection1.3Disability and discomfort glare1.4Quantities: flux, intensity, illuminance, luminance1.5Road surface reflection and r-tables1.6Mesopic factors in road lighting1.7Vision of older drivers1.8Night-time accidents and lighting1.9Relationship between light and perceived safety1.10Workshop: illuminance measurement with a lux meter
2.1Class selection according to CEN/TR 13201-12.2M classes for motorised traffic2.3C classes for conflict areas2.4P classes for pedestrians and cyclists2.5ITC-EA-02 requirements2.6Overall and longitudinal uniformity2.7Threshold increment (TI)2.8Edge illuminance ratio (EIR)2.9Semi-cylindrical and vertical illuminance2.10Case study: classification of the streets in a neighbourhood
3.1Intensity tables and EULUMDAT files3.2Calculation grids according to UNE-EN 13201-33.3Maintenance factor3.4Arrangements: single-sided, staggered, opposite3.5Mounting height, spacing and overhang3.6Calculation of road surface luminance3.7Calculation at roundabouts and junctions3.8Pedestrian crossings with dedicated lighting3.9Optimisation of the installation3.10Lab: calculation of an M3 class road in DIALux
4.1Measurement methods according to UNE-EN 13201-44.2Luminance meters and imaging luminance cameras4.3Field measurement of uniformities4.4Photometry of luminaires according to UNE-EN 130324.5Goniophotometry and uncertainty4.6Acceptance testing of installations4.7Measurement of light pollution4.8Verification reports4.9Common measurement errors4.10Practical exercise: acceptance measurement plan
5.1Tunnel lighting according to CIE 885.2Entrance zones and visual adaptation5.3Lighting of roadworks and diversions5.4Pedestrian crossings and positive contrast5.5Roundabouts and interchanges5.6Adaptive lighting and dynamic classes5.7Night-time road safety audits5.8Balancing safety and efficiency5.9Liability for lighting deficiencies5.10Case study: improvement of a pedestrian crossing with an accident record
6.1Selection of the urban road section6.2Classification of roads and areas6.3Selection of luminaires and optics6.4Complete lighting calculations6.5Glare verification6.6Analysis of singular points6.7Energy efficiency check6.8Acceptance measurement plan6.9Report and presentation6.10Final project: final review with the tutor
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within the intake, making it compatible with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIALux evo, Relux, LITESTAR 4D, LMK LabSoft and Eulumdat Tools, in free, academic or evaluation versions. Real procedures are studied: lighting calculation for an urban road, measurement of road surface luminance and a night-time audit of a pedestrian crossing. Assessment is continuous by module plus the final integrating project.
Standards covered: UNE-EN 13201-2, UNE-EN 13201-3, UNE-EN 13201-4, CEN/TR 13201-1, Royal Decree 1890/2008 (ITC-EA-02), CIE 140:2019, CIE 88:2004, UNE-EN 13032-1.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- No prior qualification is required.
- Internet connection and a computer capable of running the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 300 hours over 3 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with DIALux evo, Relux, LITESTAR 4D, LMK LabSoft and Eulumdat Tools, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute certificate, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.
No prior qualification is required; you need a computer able to run the programme software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Urban UX Course: User Experience in Cities
Online course of 300 hours in urban UX and user experience in cities, structured in 6 modules covering human-centred urban experience, urban experience research, urban service…
Sustainable Tourism Course in Heritage Cities
Online course of 300 hours in sustainable tourism in heritage cities, structured in 6 modules covering tourism in heritage cities, measuring tourism pressure, visitor flow management,…
Railway Traffic Regulation Course
Online course of 300 hours in railway traffic regulation, structured in 6 modules covering capacity and regulation, timetable design, real-time traffic regulation, tools and automation, and…
More in Civil, Rail & Smart Cities
All Civil, Rail & Smart Cities programmes → · How to apply · Fees & financing · Scholarships