CourseCivil, Rail & Smart Cities Applications open

Road Photometry and Lighting Safety Course

Online course of 300 hours in road photometry and lighting safety: 6 modules covering UNE-EN 13201-2, UNE-EN 13201-3 and UNE-EN 13201-4 applied to real cases, with an assigned technical tutor.

Duration3 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute certificate
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand the visual mechanisms involved in night-time driving.

02

Select lighting classes in accordance with the UNE-EN 13201 series.

03

Carry out photometric calculations of luminance, illuminance and glare.

04

Measure and verify installations in the field according to UNE-EN 13201-4.

05

Solve special cases such as tunnels, roundabouts and pedestrian crossings.

06

Relate photometric parameters to road safety.

07

Develop a complete road photometry project for an urban road section.

Profile

Who it's for

  • Lighting engineers.
  • Public lighting technicians.
  • Road safety auditors assessing night-time conditions.
  • Photometric laboratory technicians.
  • Electrical installation designers.
  • Urban lighting consultants.
  • Engineering or science graduates looking to move into local government.
Standards & tools

What you'll work with

  • UNE-EN 13201-2 (road lighting performance requirements)
  • UNE-EN 13201-3 (calculation of road lighting performance)
  • UNE-EN 13201-4 (methods of measuring lighting performance)
  • CEN/TR 13201-1 (guidelines on selection of lighting classes)
  • Royal Decree 1890/2008 (ITC-EA-02) (Spanish lighting level requirements for outdoor installations)
  • CIE 140:2019 (road lighting calculations)
  • CIE 88:2004 (lighting of road tunnels and underpasses)
  • UNE-EN 13032-1 (measurement and presentation of photometric data of lamps and luminaires)
  • DIALux evo
  • Relux
  • LITESTAR 4D
  • LMK LabSoft
  • Eulumdat Tools
Syllabus

6 modules

  1. 1.1Physiology of photopic, mesopic and scotopic vision
  2. 1.2Contrast, threshold and obstacle detection
  3. 1.3Disability and discomfort glare
  4. 1.4Quantities: flux, intensity, illuminance, luminance
  5. 1.5Road surface reflection and r-tables
  6. 1.6Mesopic factors in road lighting
  7. 1.7Vision of older drivers
  8. 1.8Night-time accidents and lighting
  9. 1.9Relationship between light and perceived safety
  10. 1.10Workshop: illuminance measurement with a lux meter
  1. 2.1Class selection according to CEN/TR 13201-1
  2. 2.2M classes for motorised traffic
  3. 2.3C classes for conflict areas
  4. 2.4P classes for pedestrians and cyclists
  5. 2.5ITC-EA-02 requirements
  6. 2.6Overall and longitudinal uniformity
  7. 2.7Threshold increment (TI)
  8. 2.8Edge illuminance ratio (EIR)
  9. 2.9Semi-cylindrical and vertical illuminance
  10. 2.10Case study: classification of the streets in a neighbourhood
  1. 3.1Intensity tables and EULUMDAT files
  2. 3.2Calculation grids according to UNE-EN 13201-3
  3. 3.3Maintenance factor
  4. 3.4Arrangements: single-sided, staggered, opposite
  5. 3.5Mounting height, spacing and overhang
  6. 3.6Calculation of road surface luminance
  7. 3.7Calculation at roundabouts and junctions
  8. 3.8Pedestrian crossings with dedicated lighting
  9. 3.9Optimisation of the installation
  10. 3.10Lab: calculation of an M3 class road in DIALux
  1. 4.1Measurement methods according to UNE-EN 13201-4
  2. 4.2Luminance meters and imaging luminance cameras
  3. 4.3Field measurement of uniformities
  4. 4.4Photometry of luminaires according to UNE-EN 13032
  5. 4.5Goniophotometry and uncertainty
  6. 4.6Acceptance testing of installations
  7. 4.7Measurement of light pollution
  8. 4.8Verification reports
  9. 4.9Common measurement errors
  10. 4.10Practical exercise: acceptance measurement plan
  1. 5.1Tunnel lighting according to CIE 88
  2. 5.2Entrance zones and visual adaptation
  3. 5.3Lighting of roadworks and diversions
  4. 5.4Pedestrian crossings and positive contrast
  5. 5.5Roundabouts and interchanges
  6. 5.6Adaptive lighting and dynamic classes
  7. 5.7Night-time road safety audits
  8. 5.8Balancing safety and efficiency
  9. 5.9Liability for lighting deficiencies
  10. 5.10Case study: improvement of a pedestrian crossing with an accident record
  1. 6.1Selection of the urban road section
  2. 6.2Classification of roads and areas
  3. 6.3Selection of luminaires and optics
  4. 6.4Complete lighting calculations
  5. 6.5Glare verification
  6. 6.6Analysis of singular points
  7. 6.7Energy efficiency check
  8. 6.8Acceptance measurement plan
  9. 6.9Report and presentation
  10. 6.10Final project: final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within the intake, making it compatible with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIALux evo, Relux, LITESTAR 4D, LMK LabSoft and Eulumdat Tools, in free, academic or evaluation versions. Real procedures are studied: lighting calculation for an urban road, measurement of road surface luminance and a night-time audit of a pedestrian crossing. Assessment is continuous by module plus the final integrating project.

Standards covered: UNE-EN 13201-2, UNE-EN 13201-3, UNE-EN 13201-4, CEN/TR 13201-1, Royal Decree 1890/2008 (ITC-EA-02), CIE 140:2019, CIE 88:2004, UNE-EN 13032-1.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of UNE-EN 13201-2, UNE-EN 13201-3 and UNE-EN 13201-4 applied to real cases, not as a theoretical annex.
Industry software:DIALux evo, Relux, LITESTAR 4D, LMK LabSoft and Eulumdat Tools, in free, academic or evaluation versions.
Final project:a complete road photometry project for an urban road section, from class selection to acceptance measurement plan, reviewed by your tutor.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Classify the road section
Select the urban section and classify its roads and areas.
Select luminaires and optics
Choose luminaires and optics for each lighting class.
Calculate and check glare
Run complete lighting calculations and verify glare and singular points.
Plan acceptance measurements
Check energy efficiency and draw up the acceptance measurement plan.
Final project
Present the full road photometry project with its report.
Career opportunities

Where this takes you

Lighting EngineerPublic Lighting TechnicianRoad Safety AuditorPhotometric Laboratory TechnicianElectrical Installation DesignerUrban Lighting Consultant
Admissions & scholarships

Requirements

  • No prior qualification is required.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 300 hours over 3 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with DIALux evo, Relux, LITESTAR 4D, LMK LabSoft and Eulumdat Tools, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute certificate, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.

No prior qualification is required; you need a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Road Photometry and Lighting Safety CourseEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.