CourseCivil, Rail & Smart Cities Applications open

Course on Intelligent Public Lighting and Energy Efficiency

Online course of 300 hours in smart public lighting and energy efficiency: 6 modules covering Royal Decree 1890/2008, UNE-EN 13201-2 and UNE-EN 13201-5 applied to real cases, with an assigned technical tutor.

Duration3 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute certificate
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the condition and consumption of public lighting installations.

02

Select LED luminaires using technical and green procurement criteria.

03

Design interoperable remote management and dimming systems.

04

Calculate energy efficiency and energy rating according to RD 1890/2008.

05

Reduce light pollution and its environmental effects.

06

Evaluate lighting renovation and procurement models.

07

Prepare a smart public lighting renovation project.

Profile

Who it's for

  • Public lighting technicians.
  • Lighting engineers designing road and urban schemes.
  • Municipal energy managers.
  • Energy efficiency consultants.
  • Technicians at energy service companies (ESCOs).
  • Urban maintenance managers.
  • Engineering or science graduates looking to move into local government.
Standards & tools

What you'll work with

  • Royal Decree 1890/2008 (Spanish regulation on energy efficiency in outdoor lighting installations)
  • UNE-EN 13201-2 (road lighting performance requirements)
  • UNE-EN 13201-5 (road lighting energy performance indicators)
  • UNE-EN 13201-3 (calculation of road lighting performance)
  • UNE-EN 62386 (DALI) (digital addressable lighting interface)
  • UNE-EN 60598-2-3 (luminaires for road and street lighting)
  • CIE 115:2010 (lighting of roads for motor and pedestrian traffic)
  • Law 34/2007 (air quality and protection of the atmosphere)
  • DIALux evo
  • Relux
  • QGIS
  • AutoCAD
  • LITESTAR 4D
Syllabus

6 modules

  1. 1.1Functions of outdoor lighting
  2. 1.2Inventory and condition of installations
  3. 1.3Municipal energy consumption for lighting
  4. 1.4Components: luminaire, column, control cabinet, network
  5. 1.5Lamp types and the transition to LED
  6. 1.6Light pollution and the night sky
  7. 1.7Effects on biodiversity and health
  8. 1.8Responsibilities of the local council
  9. 1.9Regulation on energy efficiency in outdoor lighting
  10. 1.10Case study: lighting inventory of a municipality
  1. 2.1Characteristics of LED modules
  2. 2.2Colour temperature and colour rendering
  3. 2.3Optics and photometric distribution
  4. 2.4Drivers and power factors
  5. 2.5Service life and depreciation according to LM-80 and TM-21
  6. 2.6Thermal management of the luminaire
  7. 2.7Surge protection
  8. 2.8Testing and certification of luminaires
  9. 2.9Green public procurement criteria
  10. 2.10Practical exercise: technical comparison of LED luminaires
  1. 3.1Dimming and time profiles
  2. 3.2DALI-2 and D4i protocols
  3. 3.3Zhaga Book 18 and NEMA sockets
  4. 3.4Point-to-point and cabinet-level remote management
  5. 3.5Lighting communication networks
  6. 3.6TALQ interoperability specification
  7. 3.7Presence detection and adaptive lighting
  8. 3.8Alarms and predictive maintenance
  9. 3.9The lighting column as a platform for smart services
  10. 3.10Lab: configuration of dimming profiles
  1. 4.1Calculation of the energy efficiency of the installation
  2. 4.2Energy rating and label
  3. 4.3Energy consumption index
  4. 4.4Energy audits of lighting
  5. 4.5Optimisation of contracted power
  6. 4.6Control cabinets and astronomical clocks
  7. 4.7UNE-EN 13201-5 performance indicators
  8. 4.8Reduction of CO2 emissions
  9. 4.9Measurement of actual savings
  10. 4.10Workshop: energy rating of an existing installation
  1. 5.1Lighting master plans
  2. 5.2Energy service contracts
  3. 5.3Lighting performance specifications
  4. 5.4Financing with IDAE and European funds
  5. 5.5Payback period calculation
  6. 5.6Preventive and corrective maintenance
  7. 5.7Management of luminaire waste
  8. 5.8Citizen participation and perception
  9. 5.9Contractual risks and guarantees
  10. 5.10Case study: economic study of an LED renovation
  1. 6.1Diagnosis of the existing installation
  2. 6.2Selection of luminaires and optics
  3. 6.3Verification lighting calculations
  4. 6.4Design of the remote management system
  5. 6.5Dimming profiles by street
  6. 6.6Final energy rating
  7. 6.7Budget and return on investment
  8. 6.8Maintenance plan
  9. 6.9Report and presentation
  10. 6.10Final project: final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within the intake, making it compatible with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIALux evo, Relux, QGIS, AutoCAD and LITESTAR 4D, in free, academic or evaluation versions. Real procedures are studied: an energy audit of a lighting installation, design of dimming profiles with remote management and an economic study of an LED renovation. Assessment is continuous by module plus the final integrating project.

Standards covered: Royal Decree 1890/2008, UNE-EN 13201-2, UNE-EN 13201-5, UNE-EN 13201-3, UNE-EN 62386 (DALI), UNE-EN 60598-2-3, CIE 115:2010, Law 34/2007.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of RD 1890/2008, UNE-EN 13201-2 and UNE-EN 13201-5 applied to real cases, not as a theoretical annex.
Industry software:DIALux evo, Relux, QGIS, AutoCAD and LITESTAR 4D, in free, academic or evaluation versions.
Final project:a smart public lighting renovation project, from diagnosis of the existing installation to budget and maintenance plan, reviewed by your tutor.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Diagnose the installation
Assess the condition and consumption of the existing lighting installation.
Select luminaires and optics
Choose LED luminaires and verify them with lighting calculations.
Design remote management
Design the remote management system and dimming profiles by street.
Rate energy performance
Calculate the final energy rating of the renovated installation.
Final project
Present the renovation project with budget, return on investment and maintenance plan.
Career opportunities

Where this takes you

Public Lighting TechnicianLighting EngineerMunicipal Energy ManagerEnergy Efficiency ConsultantEnergy Services Company TechnicianUrban Maintenance Manager
Admissions & scholarships

Requirements

  • No prior qualification is required.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 300 hours over 3 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with DIALux evo, Relux, QGIS, AutoCAD and LITESTAR 4D, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute certificate, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.

No prior qualification is required; you need a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Course on Intelligent Public Lighting and Energy EfficiencyEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.