Postgraduate Diploma in Safe Architectures and HAZOP/LOPA
800-hour online Postgraduate Diploma in Safe Architectures and HAZOP/LOPA. 8 modules covering IEC 61882, IEC 61511-1 and Sphera PHA-Pro. Assigned tutor and enrolment open.
Postgraduate Diploma in Safe Architectures and HAZOP/LOPA — studying from Singapore
Singapore is one of Asia's leading electronics manufacturing centres, with semiconductor fabrication, back-end assembly and test, and precision electronics concentrated in areas such as Tampines and Jurong. The sector also includes embedded systems for industrial and automotive use and a strong telecommunications base led by the Infocomm Media Development Authority. Major employers include global semiconductor firms and electronics manufacturers. Engineers work on hardware design, firmware, communications systems and test engineering.
Fees for Singapore: S$1,560 (Singapore dollar), with instalments and employer sponsorship available.
Relevant bodies in Singapore
Typical roles
Questions from Singapore
How are electronics and telecom engineers recognised in Singapore, and does SEIUM count?
Telecom and electronics engineering is regulated by the Infocomm Media Development Authority (IMDA), and engineers may register with the Professional Engineers Board (PEB). SEIUM's qualifications are private, not state degrees, and not accredited by any national body. Whether they are recognised is decided by employers or the relevant body, so confirm this before enrolling.
Which Singapore employers hire embedded systems and telecom engineers?
Singapore has demand from telecom operators, semiconductor and electronics manufacturers, defence and aerospace firms, and industrial automation companies. Employers generally assess hands-on skills in firmware, hardware design and testing. Your final project can evidence embedded or telecom competence, but its value is for each employer to judge.
Can I follow this from Singapore while working, and does it need a visa?
Yes, the programmes are 100% online and taught in English, so no student visa is needed to study from home in Singapore. Expect a heavy workload: 1,900 hours for a master's, 800 for a postgraduate diploma and 300 for a specialist course. Fees can be paid in instalments, and employer sponsorship is possible.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Identify process hazards using systematic techniques.
Lead and document HAZOP sessions in accordance with IEC 61882.
Apply LOPA to determine the risk reduction required.
Specify safety instrumented systems in accordance with IEC 61511.
Design control architectures with defence in depth.
Complement the analysis with fault trees and bow-tie diagrams.
Manage changes and revalidate risk studies.
Who it's for
- Process safety engineer seeking to specialise in Safe Architectures and HAZOP/LOPA.
- HAZOP facilitator seeking to specialise in Safe Architectures and HAZOP/LOPA.
- Functional safety engineer seeking to specialise in Safe Architectures and HAZOP/LOPA.
- Instrumentation and control engineer seeking to specialise in Safe Architectures and HAZOP/LOPA.
- Industrial risk analyst seeking to specialise in Safe Architectures and HAZOP/LOPA.
- Major accident prevention manager seeking to specialise in Safe Architectures and HAZOP/LOPA.
- Engineering or science graduates seeking to enter chemical and process industries.
What you'll work with
- IEC 61882
- IEC 61511-1
- IEC 61508
- IEC 61511-3
- IEC 31010
- ISO 31000
- Directive 2012/18/EU
- ANSI/ISA-18.2
8 modules · 800 h
1.1Major accidents and lessons learned1.2Seveso III Directive1.3Process safety management1.4Identification techniques: what-if and checklist1.5Risk matrices and tolerability criteria1.6ALARP principle1.7Risk management according to ISO 310001.8Techniques from IEC 310101.9Inherent safety in design1.10Case study: what-if analysis of a reactor
2.1Fundamentals according to IEC 618822.2Nodes, parameters and guide words2.3Deviations, causes and consequences2.4Safeguards and recommendations2.5P&ID preparation and documentation2.6Team composition and leadership2.7Recording and tracking of actions2.8HAZOP of procedures and software2.9Common errors in sessions2.10Workshop: HAZOP session on a P&ID
3.1LOPA scenarios from the HAZOP3.2Initiating events and frequencies3.3Independent protection layers3.4Criteria for independence and auditability3.5Conditional modifiers3.6Calculation of mitigated frequency3.7SIL assignment to instrumented functions3.8Limitations and data quality3.9Review of existing LOPAs3.10Practical exercise: LOPA of a tank overfill
4.1Lifecycle according to IEC 61511-14.2Safety requirements specification (SRS)4.31oo1, 1oo2 and 2oo3 architectures4.4Selection of sensors and final elements4.5Safety logic solvers4.6Calculation of PFDavg4.7Proof test intervals and coverage4.8Bypass and inhibition management4.9Separation between BPCS and SIS4.10Laboratory: PFDavg calculation with exSILentia
5.1Defence in depth5.2Diversity and redundancy5.3Common cause failures and beta factor5.4Safety architectures in machinery5.5Safety communications5.6Alarms as a protection layer per ISA-18.25.7Fail-safe design5.8Integration of cyber-security into the SIS5.9Architectures for regulated sectors5.10Case study: review of an SIS architecture
6.1Fault trees6.2Event trees6.3Bow-tie diagrams6.4Consequence analysis6.5OREDA reliability databases6.6Human reliability analysis6.7Sensitivity analysis6.8Integration with LOPA6.9Presentation of results6.10Practical exercise: bow-tie diagram of a leak
7.1Management of change (MOC)7.2Periodic HAZOP revalidation7.3Functional safety audits7.4Personnel competence7.5API RP 754 process safety indicators7.6Incident investigation7.7Safety culture7.8Documentation and archiving7.9Continuous improvement7.10Case study: MOC for a process modification
8.1Description of the facility8.2Definition of nodes8.3Documented HAZOP sessions8.4Selection of scenarios for LOPA8.5Calculation and SIL assignment8.6Proposed SIS architecture8.7Design recommendations8.8Follow-up plan8.9Report and presentation8.10Final review with the tutor
How you'll learn
A 100% online programme on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the enrolment period, which makes it possible to combine study with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Sphera PHA-Pro, exida exSILentia, Primatech PHAWorks, Isograph Reliability Workbench, in free, academic or evaluation versions. Practice covers real HAZOP session procedures on a real P&ID, LOPA analysis of critical scenarios and verification of PFDavg calculations. Assessment is continuous, module by module, plus the final integrative project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Identify process hazards using systematic techniques.
Lead and document HAZOP sessions in accordance with IEC 61882.
Apply LOPA to determine the risk reduction required.
Specify safety instrumented systems in accordance with IEC 61511.
Design control architectures with defence in depth.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. A university degree is not required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme comprises 800 hours in total, spread over 6 to 8 months. This is between 10 and 15 hours per week on average, compatible with a full-time job.
The programme uses Sphera PHA-Pro, exida exSILentia, Primatech PHAWorks and Isograph Reliability Workbench. Free, academic or evaluation versions are used, and the tutor indicates the open-source alternative where one exists.
An own diploma from SEIUM upon passing the continuous assessment and the integrative project. This is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Please check the recognition policy when you enrol.
Related programmes
Diploma in RMA/EDF Scheduling and WCET Analysis
Online postgraduate diploma of 800 hours in RMA/EDF Scheduling and WCET Analysis: 8 modules covering real-time system models, Rate Monotonic and EDF scheduling, shared resources and…
Postgraduate Diploma in Sector Documentation and Certification
800-hour online Postgraduate Diploma in Sector Documentation and Certification. 8 modules covering ISO/IEC/IEEE 82079-1, ISO/IEC 17065 and MadCap Flare. Assigned tutor and open enrolment.
Diploma in DDS/RTPS and QoS for Critical Systems
Online postgraduate diploma of 800 hours in DDS/RTPS and QoS for critical systems. 8 modules covering DDS architecture, the RTPS protocol, QoS policies, critical-system design, DDS…
More in Electronics, Embedded Systems & Telecom
All Electronics, Embedded Systems & Telecom programmes → · How to apply · Fees & financing · Scholarships