Master’s in High Power for HPC/UPS and Fast Charging
Online master's programme of 1,900 hours in high power for HPC/UPS and fast charging. 12 modules covering critical high-power systems, power distribution, uninterruptible power supplies, energy storage, fast-charging power electronics, grid connection and power quality, thermal management, backup generation, monitoring and control, electrical safety, and project costs and sustainability, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Analyse the power demand of critical facilities.
Design high-power electrical distribution.
Select and size UPS and storage systems.
Design the power electronics for fast charging.
Ensure power quality and grid connection.
Manage the thermal performance and monitoring of facilities.
Assess the costs, safety and sustainability of projects.
Who it's for
- Data centre electrical engineers.
- Power electronics engineers.
- Charging infrastructure engineers.
- UPS systems engineers.
- Critical facilities project managers.
- Energy efficiency engineers.
- Engineering or science graduates looking to move into data centres.
What you'll work with
- IEC 62040-3 (UPS performance and test requirements)
- IEC 61851-23 (DC EV charging stations)
- EN 50600 (data centre facilities and infrastructures)
- Royal Decree 842/2002 (REBT — Spanish Low Voltage Electrotechnical Regulation)
- UNE-EN 50160 (voltage characteristics of public supply networks)
- IEEE 519 (harmonic control in power systems)
- NFPA 70E (electrical safety in the workplace)
- Directive (EU) 2023/1791 (Energy Efficiency Directive)
- ETAP
- DIgSILENT PowerFactory
- PLECS
- EcoStruxure IT
- SKM PowerTools
12 modules
1.1Energy demand of HPC data centres1.2Power density per rack1.3Critical loads and continuity1.4Fast charging of electric vehicles1.5Common ground between UPS and chargers1.6AC and DC architectures1.7Medium voltage in critical facilities1.8Efficiency and PUE1.9AI power trends1.10Case study: power balance of a GPU cluster
2.1Transformer substations2.2Main low-voltage switchboards2.3Busways and busbar trunking2.4Rack distribution with PDUs2.548 V DC distribution2.6Protection selectivity2.7Short-circuit calculation2.8Harmonics from electronic loads2.9Spanish Low Voltage Electrotechnical Regulation (REBT)2.10Lab: distribution calculation with ETAP
3.1Offline, line-interactive and double-conversion topologies3.2Modular UPS3.3Rotary UPS3.4Eco-mode efficiency3.5Rectifiers and inverters3.6Static and maintenance bypass3.7UPS paralleling3.8IEC 62040-33.9UPS selection3.10Practical: sizing a UPS for HPC
4.1VRLA batteries4.2Lithium-ion batteries in UPS4.3Flywheels4.4Supercapacitors4.5Autonomy and sizing4.6Battery management4.7Fire safety4.8Storage and peak shaving4.9BESS at charging stations4.10Lab: comparison of storage technologies
5.1DC charger architectures5.2Stackable power modules5.3Three-phase active rectifiers5.4Isolated DC/DC converters5.5SiC semiconductors5.6Liquid-cooled cables5.7Megawatt Charging System5.8Efficiency and losses5.9Module reliability5.10Practical: sizing a 1 MW charging hub
6.1Grid access and connection6.2Contracted power and network tariffs6.3EN 50160 power quality6.4IEEE 519 harmonics6.5Power factor6.6Active filters6.7Flicker and voltage dips6.8Dynamic power management6.9Interaction with renewables6.10Case study: grid connection study for a charging station
7.1Thermal losses in equipment7.2Cooling of UPS rooms7.3Liquid cooling in HPC racks7.4Server immersion7.5Charger cooling7.6Heat recovery7.7Thermal load calculation7.8ASHRAE TC 9.9 guidelines7.9Energy efficiency7.10Lab: thermal balance of an electrical room
8.1Diesel generator sets8.2HVO fuels8.3Stationary fuel cells8.4Automatic transfer8.5Start-up and synchronisation8.6Load testing8.7Fuel storage8.8Emissions and regulations8.9Maintenance8.10Practical: transfer sequence on grid failure
9.1DCIM systems9.2Energy metering9.3Electrical SCADA9.4OCPP charger management9.5Consumption analytics9.6Alarms and events9.7Electrical predictive maintenance9.8OT cybersecurity9.9Efficiency reporting9.10Workshop: energy dashboard for a data centre
10.1Arc flash and NFPA 70E10.2Live working10.3Earthing10.4Lightning protection10.5IEC 61851-23 charger standards10.6EN 50600 for data centres10.7Fire safety10.8Signage and procedures10.9Staff training10.10Case study: arc flash study
11.1Project engineering11.2CAPEX and OPEX budgets11.3Total cost of ownership11.4Efficiency and certifications11.5Energy Efficiency Directive and data centres11.6Carbon footprint11.7Renewable energy contracts11.8Commissioning11.9Supplier management11.10Practical: TCO of two power architectures
12.1Definition of the facility12.2Load balance12.3Distribution architecture12.4UPS and storage systems12.5Power electronics12.6Thermal management12.7Monitoring and safety12.8Economic analysis12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
100% online learning on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within the intake, so you can combine it with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is ETAP, DIgSILENT PowerFactory, PLECS, EcoStruxure IT and SKM PowerTools, in free, academic or evaluation versions. Testing is studied through real procedures: UPS load tests, power quality tests and generator transfer tests. Assessment is continuous by module, plus the final Master's Thesis.
Standards covered: IEC 62040-3, IEC 61851-23, EN 50600, Royal Decree 842/2002 (REBT), UNE-EN 50160, IEEE 519, NFPA 70E, Directive (EU) 2023/1791 (energy efficiency).
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- Internet connection and a computer able to run the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with ETAP, DIgSILENT PowerFactory, PLECS, EcoStruxure IT and SKM PowerTools, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Industrial Protocols Engineering
Online master's programme of 1,900 hours in industrial protocols engineering, structured in 12 modules covering Modbus, Profibus and Profinet, EtherNet/IP and CIP, EtherCAT, CAN and CANopen,…
Master’s in End-to-End IoT Platforms Engineering
Online master's programme of 1,900 hours in end-to-end IoT platforms engineering, structured in 12 modules covering IoT solution architecture, connected device design, connectivity, messaging protocols, cloud…
Master’s in Hypervisors and Mixed-Criticality Engineering
Online master's programme of 1,900 hours in hypervisor and mixed-criticality engineering. 12 modules covering embedded virtualisation, separation hypervisors, ARINC 653 partitioning, multicore interference, guest operating systems,…
More in Electronics, Embedded Systems & Telecom
All Electronics, Embedded Systems & Telecom programmes → · How to apply · Fees & financing · Scholarships