Postgraduate DiplomaHealth, Biomechanics, Wearables & Operational Safety Applications open

Postgraduate Diploma in Wearable Biosensor Prototype Design

800-hour online Postgraduate Diploma in Wearable Biosensor Prototype Design. 8 modules covering ISO 15197 (blood glucose monitoring systems), Regulation (EU) 2017/746 (IVDR) and COMSOL Multiphysics. Dedicated tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Postgraduate Diploma in Wearable Biosensor Prototype Design — studying from Ireland

Ireland is a significant centre for medical technology and pharmaceuticals, with many international device manufacturers and a strong cluster of biomedical research in Galway, Limerick and Dublin. Biomechanics, wearable sensing and occupational health technologies are developed by companies, hospitals and research institutes such as the National University of Ireland Galway's research groups. Engineers in this area design medical devices, rehabilitation systems and safety monitoring solutions under strict regulatory requirements. Oversight comes from the Health Products Regulatory Authority and the Health and Safety Authority.

Fees for Ireland: €1,790 (Euro), with instalments and employer sponsorship available.

Relevant bodies in Ireland

  • Health Products Regulatory Authority (HPRA)
  • Health and Safety Authority (HSA)
  • Irish Medtech Association (IMTA)
  • Engineers Ireland

Typical roles

  • Biomedical Engineer
  • Medical Device Engineer
  • Biomechanics Engineer
  • Wearables Systems Engineer

Questions from Ireland

Will this qualification be recognised by professional bodies in Ireland for this area?

SEIUM's qualifications are private qualifications, not official state degrees, and they are not accredited by any national body. Recognition is decided by individual employers or the relevant body. In Ireland, engineers in this field may look to Engineers Ireland for professional membership, but completing a SEIUM programme does not by itself grant membership of any body. Check requirements directly with the body concerned before enrolling.

How might this training be used by employers in Ireland working in this area?

Employers in Ireland decide for themselves how much weight to give a private online qualification. Many assess it alongside your existing experience, the final project and your portfolio. Roles in medical devices, occupational health and workplace safety may value specialist knowledge, but there is no guarantee of recognition or of any salary or promotion outcome. Ask prospective employers whether they would accept the qualification.

Can I study this alongside a full-time job, and does my employer need to fund it?

Programmes are fully online and taught in English, so you can study from home at your own pace around work. Master's programmes are 1,900 hours, postgraduate diplomas 800 hours and specialist courses 300 hours, so plan your weekly commitment accordingly. Fees can be paid in instalments, and employer sponsorship is possible if your company agrees. Each student is assigned a technical tutor for support.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Describe the principles of bio-recognition and transduction.

02

Design amperometric and potentiometric electrochemical biosensors.

03

Compare optical and physical transduction strategies for wearables.

04

Select flexible materials and manufacturing processes.

05

Design low-noise, low-power readout electronics.

06

Process signals to compensate for drift, temperature and artefacts.

07

Plan the analytical validation and regulatory pathway of the prototype.

Profile

Who it's for

  • Biosensor engineer looking to specialise in Wearable Biosensor Prototype Design.
  • Applied electrochemistry researcher looking to specialise in Wearable Biosensor Prototype Design.
  • Biomedical hardware engineer looking to specialise in Wearable Biosensor Prototype Design.
  • Wearable device R&D engineer looking to specialise in Wearable Biosensor Prototype Design.
  • Analytical validation specialist looking to specialise in Wearable Biosensor Prototype Design.
  • Biomedical prototyping engineer looking to specialise in Wearable Biosensor Prototype Design.
  • Engineering or science graduates seeking to enter health technology.
Standards & tools

What you'll work with

  • ISO 15197 (blood glucose monitoring systems)
  • Regulation (EU) 2017/746 (IVDR)
  • Regulation (EU) 2017/745 (MDR)
  • ISO 10993-1 (biological evaluation)
  • ISO 14971 (risk management)
  • IEC 60601-1 (safety of medical electrical equipment)
  • CLSI EP05-A3 (evaluation of precision)
  • ISO 13485 (quality management systems)
Syllabus

8 modules · 800 h

  1. 1.1Elements of a biosensor: receptor, transducer and readout
  2. 1.2Biofluids: sweat, interstitial fluid, saliva and tears
  3. 1.3Biomarkers of interest in wearables
  4. 1.4Sensitivity, selectivity and limit of detection
  5. 1.5Drift, hysteresis and stability
  6. 1.6Correlation between sweat and blood
  7. 1.7Physiological limitations of measurement
  8. 1.8State of the portable biosensor market
  9. 1.9Review of the scientific literature
  10. 1.10Workshop: analysis of a paper on a sweat sensor
  1. 2.1Potentiometry and ion-selective electrodes
  2. 2.2Amperometry and enzymatic sensors
  3. 2.3Cyclic and square-wave voltammetry
  4. 2.4Impedance spectroscopy
  5. 2.5Solid-state reference electrode
  6. 2.6Redox mediators and sensor generations
  7. 2.7Miniaturised potentiostats
  8. 2.8Calibration and compensation for pH and temperature
  9. 2.9Electrochemical interferences
  10. 2.10Laboratory: calibration of a glucose sensor
  1. 3.1Photoplethysmography and SpO2
  2. 3.2Colorimetry in microfluidics
  3. 3.3Fluorescence and optical sensors
  4. 3.4Skin temperature sensors
  5. 3.5Body bioimpedance
  6. 3.6Strain and pressure sensors
  7. 3.7Multisensor fusion
  8. 3.8Motion artefacts
  9. 3.9Comparison of modalities
  10. 3.10Practice: designing a PPG channel
  1. 4.1Flexible substrates: PET, PI and PDMS
  2. 4.2Screen printing of electrodes
  3. 4.3Inkjet printing and functional inks
  4. 4.4Nanomaterials: graphene and nanotubes
  5. 4.5Enzyme immobilisation
  6. 4.6Paper and polymer microfluidics
  7. 4.7Medical-grade skin adhesives
  8. 4.8Encapsulation and shelf life
  9. 4.9Scaling from laboratory to production
  10. 4.10Workshop: manufacturing workflow for a screen-printed patch
  1. 5.1Transimpedance amplifiers
  2. 5.2Integrated analogue front-ends
  3. 5.3ADC conversion and resolution
  4. 5.4Consumption and power supply
  5. 5.5BLE and NFC communication
  6. 5.6Flexible PCB design
  7. 5.7Shielding and noise
  8. 5.8Acquisition firmware
  9. 5.9On-device signal processing
  10. 5.10Laboratory: assembling a potentiostat front-end
  1. 6.1Filtering and drift removal
  2. 6.2Signal quality detection
  3. 6.3Personalised calibration
  4. 6.4Concentration regression models
  5. 6.5Machine learning in biosensing
  6. 6.6Cross-validation and overfitting
  7. 6.7Visualisation for users and clinicians
  8. 6.8Data security and privacy
  9. 6.9Cloud management
  10. 6.10Practice: calibration model using real data
  1. 7.1In vitro tests against a reference
  2. 7.2Pilot studies in volunteers
  3. 7.3Bland-Altman analysis and Clarke grid
  4. 7.4Regulation (EU) 2017/745 (MDR) and classification
  5. 7.5Biocompatibility under ISO 10993
  6. 7.6Usability under IEC 62366-1
  7. 7.7Software as a medical device
  8. 7.8Risk management under ISO 14971
  9. 7.9Difference between wellness and medical use
  10. 7.10Case study: regulatory strategy for a lactate patch
  1. 8.1Selection of the biomarker and use case
  2. 8.2Transducer design
  3. 8.3Electronics design
  4. 8.4Manufacturing plan
  5. 8.5Calibration algorithm
  6. 8.6Validation plan
  7. 8.7Regulatory analysis
  8. 8.8Results and improvements
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100 % online training on the SEIUM campus, with downloadable material, recorded classes and a dedicated technical tutor. No fixed timetable: students progress at their own pace within the intake, making it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is COMSOL Multiphysics, MATLAB, Python (SciPy), KiCad, PSTrace (PalmSens), in free, academic or evaluation versions. Tests are studied using real electrochemical characterisation procedures with a potentiostat, a screen-printed electrode fabrication laboratory, and validation against a reference analyser. Assessment is continuous, module by module, plus the final integrative project.

Hands-on practical workwith industry-standard software, simulation, real case studies and guided practical exercises.
Evidence-focused final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:faculty with professional experience in the field and in real industry projects.
Flexible format(100% online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, cybersecurity and regulatory compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Selection of the biomarker and use case

Describe the principles of bio-recognition and transduction.

Transducer design

Design amperometric and potentiometric electrochemical biosensors.

Electronics design

Compare optical and physical transduction strategies for wearables.

Manufacturing plan

Select flexible materials and manufacturing processes.

Calibration algorithm

Design low-noise, low-power readout electronics.

Career opportunities

Where this takes you

Biosensor engineerApplied electrochemistry researcherBiomedical hardware engineerWearable device R&D engineerAnalytical validation specialistBiomedical prototyping engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme software.
  • Sufficient English to follow technical regulatory texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with full-time work.

You will work with COMSOL Multiphysics, MATLAB, Python (SciPy), KiCad, PSTrace (PalmSens). Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the advanced programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Wearable Biosensor Prototype DesignEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.