Diploma in Power Networks in Military Vehicles
600-hour online postgraduate diploma in military vehicle power networks: 28 V architecture, batteries, MIL-STD-1275E, protection, EMC, load management and MIL-STD-810H qualification, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Define the on-board network architecture and the power balance for each operating mode, including silent watch.
Size the alternator, batteries, auxiliary power unit and supercapacitors for the mission profile.
Verify power quality against MIL-STD-1275E limits and design the power conditioning.
Calculate cable sizes, voltage drops and short circuits and coordinate the protection devices.
Apply MIL-STD-461G to the vehicle with shielding, filtering and route segregation.
Design load management, automatic load shedding and system supervision.
Plan environmental qualification under MIL-STD-810H and its traceability matrix.
Who it's for
- Electrical engineers at manufacturers and integrators of defence land vehicles.
- Integration engineers installing communications equipment and sensors in vehicles.
- Wiring harness and distribution system designers.
- EMC and environmental test technicians for vehicle-mounted equipment.
- Maintenance technicians at vehicle depots and workshops.
- Electrical, electronic or automotive engineering graduates who want to specialise in military vehicles.
What you'll work with
- MIL-STD-1275E (characteristics of 28 V DC electrical systems in military vehicles)
- Def Stan 61-5 Part 6 (28 V DC electrical systems in military vehicles)
- MIL-STD-461G (control of electromagnetic interference characteristics)
- MIL-STD-464C (system-level electromagnetic environmental effects)
- MIL-STD-810H (environmental engineering considerations and laboratory tests)
- MIL-DTL-38999 (high-density circular connectors)
- ISO 16750-2 (electrical loads on road vehicle equipment)
- IEC 62619 (safety of industrial lithium batteries)
8 modules
1.1Twenty-eight volt networks and higher-voltage architectures1.2Star, ring and distributed bus topologies1.3Power balance and load profile by mission1.4Silent watch and engine-off operation1.5External power and parked connection1.6Separating the service and starting networks1.7Zonal distribution and distribution boxes1.8Chassis ground as return conductor1.9Growth margin for future loads1.10Documenting the single-line diagram
2.1High-output alternator and its cooling2.2Voltage regulator and set point2.3Lead-acid versus lithium iron phosphate2.4Capacity testing and extreme cold starting2.5Auxiliary power unit and its integration2.6Managing charging of parallel batteries2.7Supercapacitors to support starting2.8Current sharing between multiple sources2.9Generator efficiency at variable speed2.10Battery state monitoring
3.1Requirements of standardisation agreement STANAG 40743.2MIL-STD-1275 limits for low-voltage networks3.3Cranking transients and voltage dips3.4Voltage spikes and their allowable duration3.5Superimposed ripple and harmonic content3.6Reverse polarity and associated protection3.7Short interruptions and load behaviour3.8Equipment immunity testing to disturbances3.9Line conditioners and input filters3.10Conformity documentation for each equipment item
4.1Cable sizing by voltage drop4.2Current capacity by ambient temperature4.3Fuses, circuit breakers and protection coordination4.4Electronic distribution with smart fuses4.5Circular connectors and ingress protection rating4.6Wiring harnesses, shielding and clamping4.7Mechanical protection against vibration and abrasion4.8Marking and identification of conductors4.9Short-circuit calculation in the on-board network4.10Harness maintenance and diagnostics
5.1MIL-STD-461 tests by category5.2Broadband conducted and radiated emissions5.3Immunity to high-intensity electromagnetic fields5.4Electrostatic discharge and input protection5.5Three-hundred-and-sixty-degree shield termination5.6Shielding the electronics compartment5.7Segregating power and signal routes5.8Feed-through filters and their installation5.9Anechoic chamber testing and its budget5.10Programme EMC control plan
6.1Load prioritisation and automatic shedding6.2Data bus for distribution control6.3Per-circuit current monitoring6.4Fault diagnosis and fault codes6.5Thermal management of power electronics6.6Protection against deep battery discharge6.7Electrical control panel interface6.8Electrical event logging for maintenance6.9Emergency modes and essential loads6.10Controller software updates
7.1Equipment environmental qualification plan7.2Applicable MIL-STD-810 tests7.3Random vibration and transport profiles7.4Mechanical shock and drop testing7.5Thermal cycling and high relative humidity7.6Protection against dust, sand and salt fog7.7Watertightness and fording tests7.8Traceability matrix between requirement and test7.9Qualification report and customer acceptance7.10Qualification by similarity and its justification
8.1Gathering the load profile by operating mode8.2Sizing generation and storage8.3Defining the topology and distribution zones8.4Calculating cable sizes and voltage drops8.5Selecting and coordinating protection devices8.6Designing the load shedding strategy8.7Preparing the electromagnetic control plan8.8Scheduling the environmental test campaign8.9Building the traceability matrix8.10Presenting the qualification file
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within each intake, so you can combine the programme with your job.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is MATLAB/Simulink, Simscape Electrical, Capital Harness, Excel, in free, academic or evaluation versions. Cases are studied on real electrical networks of wheeled and tracked armoured vehicles and logistic vehicles. Assessment is continuous, module by module, plus the final integrated project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- An internet connection and a computer able to run the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 600 hours over 6–9 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with MATLAB/Simulink, Simscape Electrical, Capital Harness and Excel, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.
Prior technical training or professional experience in the sector (no university degree required), a computer able to run the programme software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Diploma in Critical Avionics and DO-178C Certification
Online postgraduate diploma of 800 hours in critical avionics and DO-178C certification. 8 modules covering critical avionics architectures, DO-178C processes, requirements and design, coding and verification,…
Diploma in OT Cybersecurity for Military Vehicles
Online postgraduate diploma of 800 hours in OT cybersecurity for military vehicles. 8 modules covering vetronics architectures, OT security, threat analysis and risk assessment, onboard protection,…
Diploma in Multinational Certification (NATO/US/EU)
Online postgraduate diploma of 800 hours in multinational certification (NATO/US/EU): 8 modules covering certification in multinational programmes, European military airworthiness (EMAR 21, EMACC), US certification (MIL-HDBK-516C),…
More in Defense, Military Engineering & Land Systems
All Defense, Military Engineering & Land Systems programmes → · How to apply · Fees & financing · Scholarships