Postgraduate DiplomaDefense, Military Engineering & Land Systems Applications open

Diploma in EW Infrastructure Security

Online postgraduate diploma of 800 hours in EW Infrastructure Security. 8 modules covering electromagnetic environments, shielding, line filtering and protection, earthing and bonding, protection to military standards (MIL-STD-188-125-1, IEC 61000-2-9), emanations security (TEMPEST) and facility security management, with an assigned technical tutor.

Duration6–8 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Diploma in EW Infrastructure Security — studying from Canada

Canada's defence sector is centred on procurement and sustainment through the Department of National Defence and Defence Research and Development Canada. Industrial activity spans land vehicles, naval systems, avionics and electronics, with firms in Ontario, Québec, Nova Scotia and British Columbia. Companies such as General Dynamics Land Systems Canada and Lockheed Martin Canada are notable employers, alongside a broad base of small and medium suppliers. Engineers work on systems integration, vehicle protection, logistics and sustainment, operating within strict security and export control frameworks.

Fees for Canada: C$2,330 (Canadian dollar), with instalments and employer sponsorship available.

Relevant bodies in Canada

  • Department of National Defence (DND)
  • Defence Research and Development Canada (DRDC)
  • Canadian Association of Defence and Security Industries (CADSI)
  • Public Services and Procurement Canada

Typical roles

  • Defence Systems Engineer
  • Land Systems Engineer
  • Systems Integration Engineer
  • Sustainment Engineer

Questions from Canada

Which Canadian bodies or processes govern defence engineering recognition?

Defence engineering in Canada often involves government procurement and security clearances, and engineers typically hold provincial Professional Engineer licences where a title is required. SEIUM's qualifications are private and not official state degrees or accredited by a national body, so they do not confer licensing or clearance. Recognition is for employers or the relevant body to decide, so verify this first.

Would Canadian defence or land systems employers accept this training?

Canadian defence employers and contractors generally rely on security clearance, licensing and demonstrated experience. A private qualification may support your application, but it is unlikely to replace those requirements, and its acceptance is up to each employer. A SEIUM final project can help show applied skill, so discuss expectations with prospective employers early.

Can I study remotely while working, and what are the costs and language demands?

Yes, the programmes are fully online, so you can study from Canada or elsewhere without a student visa, and fit sessions around work. Specialist courses are 300 hours, postgraduate diplomas 800 and master's 1,900. Teaching is in English, supported by an assigned technical tutor. Fees are payable in instalments, and employer sponsorship may be available.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand intense electromagnetic environments and their effects on infrastructure.

02

Design shielding, filtering and earthing for facilities.

03

Apply standards for protection against electromagnetic pulses.

04

Manage emanations security in line with TEMPEST.

05

Integrate physical, information and electromagnetic security.

06

Verify protection through standardised testing.

07

Draw up protection and maintenance plans for sensitive facilities.

Profile

Who it's for

  • Electromagnetic protection engineers.
  • EMC engineers moving into infrastructure hardening.
  • Facility security managers responsible for sensitive sites.
  • TEMPEST specialists.
  • Critical communications infrastructure engineers.
  • Technical security auditors.
  • Engineering or science graduates seeking to enter the defence sector.
Standards & tools

What you'll work with

  • MIL-STD-188-125-1 (HEMP protection for fixed facilities)
  • IEC 61000-2-9 (description of the radiated HEMP environment)
  • IEC 61000-5-3 (HEMP protection concepts)
  • MIL-STD-461G (electromagnetic compatibility)
  • MIL-STD-464C (electromagnetic environmental effects for systems)
  • SDIP-27 (NATO TEMPEST standards)
  • IEEE 299 (shielding effectiveness of enclosures)
  • ISO/IEC 27001 (information security management)
  • CST Studio Suite
  • Keysight PathWave
  • MATLAB
  • EMC Studio
Syllabus

8 modules

  1. 1.1Spectrum and sources of interference
  2. 1.2System electromagnetic environments
  3. 1.3High-altitude electromagnetic pulse: description in the standards
  4. 1.4Lightning strikes
  5. 1.5Intentional interference: conceptual framework
  6. 1.6Coupling into cables and apertures
  7. 1.7Equipment susceptibility
  8. 1.8Effects on infrastructure
  9. 1.9Threat assessment
  10. 1.10Case study: electromagnetic environment of a station
  1. 2.1Shielding theory
  2. 2.2Shielding materials
  3. 2.3Shielded enclosures
  4. 2.4Gaskets and doors
  5. 2.5Apertures and ventilation
  6. 2.6Penetration panels
  7. 2.7Effectiveness according to IEEE 299
  8. 2.8Shielding degradation
  9. 2.9Design of protected rooms
  10. 2.10Lab: shielding effectiveness measurement
  1. 3.1Power filters
  2. 3.2Surge protection
  3. 3.3Data line protection
  4. 3.4Optical fibre as isolation
  5. 3.5Points of entry
  6. 3.6Coordination of protection devices
  7. 3.7Current injection testing
  8. 3.8Filter maintenance
  9. 3.9Applicable standards
  10. 3.10Practical exercise: surge protection plan
  1. 4.1Earthing systems
  2. 4.2Equipotential meshes
  3. 4.3Safety and signal earths
  4. 4.4Ground loops
  5. 4.5Lightning protection
  6. 4.6Earth resistance measurement
  7. 4.7Design for mobile installations
  8. 4.8Periodic inspection
  9. 4.9Common mistakes
  10. 4.10Case study: earthing design for a communications centre
  1. 5.1MIL-STD-188-125-1
  2. 5.2IEC 61000-2-9 and 61000-5-3
  3. 5.3MIL-STD-464C
  4. 5.4Design criteria
  5. 5.5Verification testing
  6. 5.6Acceptance testing
  7. 5.7Maintenance programmes
  8. 5.8Protection surveillance
  9. 5.9Transportable installations
  10. 5.10Practical exercise: compliance matrix for a facility
  1. 6.1The TEMPEST concept
  2. 6.2SDIP-27 and levels
  3. 6.3Facility zoning
  4. 6.4Red-black separation
  5. 6.5Approved equipment
  6. 6.6Zone measurements
  7. 6.7Equipment installation
  8. 6.8TEMPEST inspections
  9. 6.9Integration with information security
  10. 6.10Lab: TEMPEST zoning audit
  1. 7.1Comprehensive risk analysis
  2. 7.2Physical security
  3. 7.3Cybersecurity
  4. 7.4Service continuity
  5. 7.5Backup power
  6. 7.6Operating procedures
  7. 7.7Staff training
  8. 7.8Audits
  9. 7.9Continuous improvement
  10. 7.10Workshop: security plan for a sensitive facility
  1. 8.1Facility description
  2. 8.2Environment assessment
  3. 8.3Shielding design
  4. 8.4Filtering and earthing
  5. 8.5Emanations security
  6. 8.6Verification plan
  7. 8.7Maintenance plan
  8. 8.8Conclusions
  9. 8.9Report and presentation
  10. 8.10Final project: final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so the programme fits around your job.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is CST Studio Suite, Keysight PathWave, MATLAB and EMC Studio, in free, academic or evaluation versions. Practical work is based on real procedures: measuring the shielding effectiveness of an enclosure, designing a surge protection plan and auditing TEMPEST zoning. Assessment is continuous by module, plus the final project.

Standards covered: MIL-STD-188-125-1, IEC 61000-2-9, IEC 61000-5-3, MIL-STD-461G, MIL-STD-464C, SDIP-27, IEEE 299, ISO/IEC 27001.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of MIL-STD-188-125-1, IEC 61000-2-9 and IEC 61000-5-3 applied to real cases, not as a theoretical annex.
Industry software:CST Studio Suite, Keysight PathWave, MATLAB and EMC Studio, in free, academic or evaluation versions.
Final project:An integrated electromagnetic security design for a sensitive facility, from environment assessment to verification and maintenance plans, reviewed by your tutor.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Facility and environment
Describe the facility and assess its electromagnetic environment.
Shielding design
Design the shielding of the protected areas.
Filtering and earthing
Specify line filtering, surge protection and the earthing scheme.
Emanations and verification
Define TEMPEST zoning and the verification test plan.
Final project
Complete facility protection and maintenance plan, reviewed by your tutor.
Career opportunities

Where this takes you

Electromagnetic protection engineerElectromagnetic compatibility engineerFacility security managerTEMPEST specialistCritical communications infrastructure engineerTechnical security auditor
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • An internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours over 6–8 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with CST Studio Suite, Keysight PathWave, MATLAB and EMC Studio, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.

Prior technical training or professional experience in the sector (no university degree required), a computer able to run the software, and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Diploma in EW Infrastructure SecurityEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.