Postgraduate Diploma in Secure Acquisition of ECG/PPG/EEG/EMG
Online Postgraduate Diploma of 800 h in Secure Acquisition of ECG/PPG/EEG/EMG. 8 modules with IEC 60601-1 (medical electrical equipment safety), IEC 60601-1-2 (electromagnetic compatibility) and LTspice. Assigned tutor and open enrolment.
Postgraduate Diploma in Secure Acquisition of ECG/PPG/EEG/EMG — studying from South Africa
Health technology and occupational safety are important in South Africa, where mining, manufacturing and healthcare all require strong safety engineering. The Medicines Control Council regulates medical devices, and the Department of Employment and Labour enforces workplace health and safety legislation. Hospitals, medical device distributors and research groups at universities use biomechanics and wearable technology to improve care and worker protection. Demand exists for engineers who can combine human factors knowledge with regulatory compliance.
Fees for South Africa: R 33 400 (South African rand), with instalments and employer sponsorship available.
Relevant bodies in South Africa
Typical roles
Questions from South Africa
Will a SEIUM qualification be recognised by the professional bodies in South Africa for this area?
SEIUM qualifications are private qualifications, not official state degrees, and they are not accredited by any South African body. Engineering registration in South Africa is handled by the Engineering Council of South Africa (ECSA), which registers people based on their own accredited training and experience. Recognition of a private qualification is therefore decided by individual employers or the relevant professional body, so check with them before enrolling.
How might this qualification be used by employers in South Africa in health-related engineering or occupational safety?
Employers in medical devices, occupational health, and workplace safety may value advanced, specialised knowledge in biomechanics and wearable technology, especially when paired with practical experience. Because the qualification is private rather than state-recognised, its weight depends on each employer's view. Speak to potential employers in your sector about whether they would consider it alongside your existing qualifications and work history.
Can I study this programme alongside full-time work from South Africa, and is there a time zone or language issue?
The programme is 100% online and taught in English, so you can study from home without a student visa. Master's programmes total 1,900 hours, postgraduate diplomas 800 hours and specialist courses 300 hours, with an assigned technical tutor and fees payable in instalments. Employer sponsorship is possible. Confirm the schedule and time-zone expectations with SEIUM before enrolling, as these details are not covered here.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Describe the origin and characteristics of biopotentials and optical signals.
Design amplification, filtering and conversion stages for ECG, PPG, EEG and EMG.
Apply patient electrical safety requirements.
Ensure the electromagnetic compatibility of the acquisition system.
Assess and improve signal quality in the presence of artefacts.
Protect the transmission and storage of physiological data.
Plan the validation and CE marking of the system.
Who it's for
- Biomedical hardware engineer who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Sensor engineer who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Electrical safety compliance engineer who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Medical device validation engineer who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Signal processing engineer who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Regulatory affairs specialist who wants to specialise in Secure Acquisition of ECG/PPG/EEG/EMG.
- Graduates in engineering or sciences seeking to enter the medical devices sector.
What you'll work with
- IEC 60601-1 (medical electrical equipment safety)
- IEC 60601-1-2 (electromagnetic compatibility)
- IEC 60601-2-25 (electrocardiographs)
- IEC 60601-2-26 (electroencephalographs)
- IEC 60601-2-40 (electromyographs)
- ISO 80601-2-61 (pulse oximeters)
- IEC 62304 (medical device software)
8 modules · 800 h
1.1Physiological origin of ECG, EEG and EMG1.2Photoplethysmography: optical principle1.3Typical amplitudes and bandwidths1.4Wet, dry and textile electrodes1.5Electrode-skin interface and impedance1.6Motion artefacts1.7Electrode placement and the 10-20 system1.8Reflective and transmissive PPG sensors1.9Sensor selection by application1.10Laboratory: ECG recording with different electrodes
2.1Instrumentation amplifiers2.2Common-mode rejection2.3Active right-leg circuit2.4Analogue anti-aliasing filters2.5A/D conversion: resolution and sampling rate2.6Integrated front-ends for biopotentials2.7Optical front-ends for PPG2.8Noise and noise budget2.9Power consumption and low-power design2.10Practical: designing an ECG front-end
3.1IEC 60601-1: general requirements3.2Applied parts type B, BF and CF3.3Leakage currents and limits3.4Insulation and means of protection3.5Defibrillation protection3.6Battery power and charging3.7IEC 60601-2-25 and 2-263.8IEC 60601-1-11 for home healthcare environments3.9Electrical safety testing3.10Workshop: insulation analysis of an ECG wearable
4.1IEC 60601-1-24.2Immunity to electrostatic discharge4.350 Hz mains interference4.4Radio emissions from the device4.5Shielding and PCB design4.6Coexistence with BLE and Wi-Fi4.7Testing in accredited laboratories4.8EMC risk management4.9EMC documentation4.10Practical: EMC test plan for an EMG sensor
5.1Signal quality indices for ECG and PPG5.2Loose electrode detection5.3Digital filtering: FIR and IIR5.4Baseline drift removal5.5Notch and adaptive filters5.6Motion artefact reduction using an accelerometer5.7Source separation by ICA in EEG5.8Validation against reference equipment5.9Bland-Altman agreement metrics5.10Laboratory: artefact filtering in an EMG recording
6.1On-device data encryption6.2BLE security: pairing and bonding6.3Integrity and timestamps6.4Synchronisation of multiple sensors6.5Storage and packet loss6.6Cybersecurity according to IEC 81001-5-16.7GDPR and biometric data6.8EDF and DICOM formats for signals6.9Interoperability with FHIR6.10Case study: threat model of a connected Holter monitor
7.1Device classification under the MDR7.2Risk management under ISO 149717.3Essential performance requirements7.4IEC 62304 for device software7.5Clinical validation of accuracy7.6ISO 10993 biocompatibility of electrodes7.7Usability in the home environment7.8Technical documentation7.9Post-market surveillance7.10Practical: risk matrix for a PPG sensor
8.1Definition of signals and use8.2Sensor selection8.3Front-end design8.4Electrical safety analysis8.5EMC plan8.6Signal quality processing8.7Data security8.8Validation plan8.9Report and presentation8.10Final review with the tutor
How you'll learn
Fully 100 % online training on the SEIUM campus, with downloadable material, recorded lectures and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is LTspice, Altium Designer, MATLAB, Python (SciPy), LabVIEW, in free, academic or evaluation versions. Tests are studied using real procedures for leakage current tests, electromagnetic compatibility chambers and validation with patient simulators. Assessment is continuous per module plus the final integrative project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Describe the origin and characteristics of biopotentials and optical signals.
Design amplification, filtering and conversion stages for ECG, PPG, EEG and EMG.
Apply patient electrical safety requirements.
Ensure the electromagnetic compatibility of the acquisition system.
Assess and improve signal quality in the presence of artefacts.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient command of Spanish to follow technical regulatory texts.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme consists of 800 hours in total, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.
The programme works with LTspice, Altium Designer, MATLAB, Python (SciPy) and LabVIEW. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
A SEIUM Institute own diploma upon passing the continuous assessment and the integrative project. This is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a Course or Postgraduate Diploma in the same area are credited towards the higher programme. Check the recognition policy when you enrol.
Related programmes
Postgraduate Diploma in Physiological Event Detection Algorithms
Online 800-hour Postgraduate Diploma in Physiological Event Detection Algorithms. 8 modules covering ANSI/AAMI EC57 (evaluation of heart rhythm algorithms), IEC 60601-2-47 (ambulatory electrocardiography systems) and Python…
Postgraduate Diploma in Life Cycle Testing and Electrical Safety
Online 800-hour Postgraduate Diploma in Life Cycle Testing and Electrical Safety. 8 modules covering IEC 60601-1 (safety of medical electrical equipment), IEC 62368-1 (safety of ICT…
Postgraduate Diploma in Post-Market Surveillance and PMCF
Online 800-hour Postgraduate Diploma in Post-Market Surveillance and PMCF. 8 modules covering Regulation (EU) 2017/745 (medical devices, arts. 83 to 92), MDCG 2020-7 (PMCF plan template)…
More in Health, Biomechanics, Wearables & Operational Safety