Postgraduate Diploma in Refrigeration and Efficiency (PUE/DCiE)

Online 800-hour Postgraduate Diploma in Refrigeration and Efficiency (PUE/DCiE). 8 modules covering ISO/IEC 30134-2 (energy effectiveness, PUE), EN 50600-4-2 (PUE indicator in data centres) and Cadence Reality DC Design. Assigned tutor and enrolment open.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Postgraduate Diploma in Refrigeration and Efficiency (PUE/DCiE) — studying from South Africa

Energy is a defining sector in South Africa, with Eskom operating the bulk of the national generation and transmission network and independent power producers increasingly contributing renewable capacity. Grid modernisation, renewable integration and distribution management create steady demand for engineers. The National Energy Regulator of South Africa oversees electricity regulation, while municipalities manage local distribution. Energy engineers typically work on generation, transmission, protection and system planning.

Fees for South Africa: R 16 700 (South African rand), with instalments and employer sponsorship available.

Relevant bodies in South Africa

  • National Energy Regulator of South Africa (NERSA)
  • South African Bureau of Standards (SABS)
  • South African Institute of Electrical Engineers (SAIEE)

Typical roles

  • Power Systems Engineer
  • Grid Planning Engineer
  • Protection Engineer
  • Renewable Energy Engineer

Questions from South Africa

Which South African bodies regulate energy and networks engineers, and would SEIUM count?

Energy engineers in South Africa are registered through ECSA, and the electricity sector is regulated by NERSA. Utilities and networks often require registered professionals for certain work. SEIUM is a private online institute, and its qualifications are not official state degrees or accredited by a national body. Recognition is for employers and the relevant body to decide, so verify this before enrolling.

Will this qualification help me find work with energy or network employers in South Africa?

South Africa's energy sector includes Eskom, municipalities, independent power producers and grid-related firms, which typically hire registered and experienced engineers. A private online qualification may support your application but does not guarantee a role. Check with target employers how they view it, and combine it with practical experience where possible.

How do I manage the workload, and can I get help with fees?

The programme is fully online and taught in English, so you need good English, and no student visa is needed to study from home. Master's programmes are 1,900 hours, postgraduate diplomas 800 hours and specialist courses 300 hours, with an assigned technical tutor and a final project. Fees are payable in instalments, and employer sponsorship may be possible, so ask your employer whether they would support the cost.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the energy consumption of a data centre by subsystem.

02

Apply thermodynamics to cooling cycles.

03

Compare air, water and direct liquid cooling systems.

04

Optimise airflow with aisle containment.

05

Calculate PUE, DCiE and complementary metrics such as WUE.

06

Implement control strategies and free cooling.

07

Propose a plan to improve the efficiency and sustainability of the data centre.

Profile

Who it's for

  • Data centre cooling engineer looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • Data centre energy efficiency manager looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • CFD simulation specialist looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • HVAC engineer looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • Data centre operations manager looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • Digital sustainability consultant looking to specialise in Refrigeration and Efficiency (PUE/DCiE).
  • Engineering or science graduates looking to enter the data centre sector.
Standards & tools

What you'll work with

  • ISO/IEC 30134-2 (energy effectiveness, PUE)
  • EN 50600-4-2 (PUE indicator in data centres)
  • ASHRAE TC 9.9 (thermal guidelines for data centres)
  • EN 50600-2-3 (environmental control in data centres)
  • Delegated Regulation (EU) 2024/1364 (data centre rating scheme)
  • Regulation (EU) 2024/573 (fluorinated gases)
  • ISO 50001 (energy management systems)
Syllabus

8 modules · 800 h

  1. 1.1Architecture of a data centre
  2. 1.2Power densities per rack
  3. 1.3Electrical distribution and UPS
  4. 1.4Uptime Institute Tier classification
  5. 1.5EN 50600 standard
  6. 1.6IT and non-IT energy balance
  7. 1.7PUE and DCiE indicators
  8. 1.8ISO/IEC 30134-2 standard
  9. 1.9Energy Efficiency Directive (EU) 2023/1791 and data centres
  10. 1.10Case study: PUE calculation for a server room
  1. 2.1Thermal load of IT equipment
  2. 2.2Applied psychrometrics
  3. 2.3ASHRAE TC 9.9 thermal envelopes
  4. 2.4Equipment classes A1 to A4
  5. 2.5Dew point and humidity
  6. 2.6Airflow and flow rate per kW
  7. 2.7Server delta T
  8. 2.8Supply and return temperatures
  9. 2.9Reliability versus temperature
  10. 2.10Workshop: thermal balance of a server room
  1. 3.1CRAC and CRAH units
  2. 3.2Water chillers and condensation
  3. 3.3Cooling towers
  4. 3.4Air-side and water-side free cooling
  5. 3.5Indirect evaporative cooling
  6. 3.6In-row and rear-door cooling
  7. 3.7Direct-to-chip liquid cooling
  8. 3.8Single-phase and two-phase immersion
  9. 3.9Refrigerants and the F-gas Regulation
  10. 3.10Laboratory: comparison of systems by climate
  1. 4.1Hot and cold aisles
  2. 4.2Aisle containment
  3. 4.3Blanking panels and sealing
  4. 4.4Bypass and recirculation
  5. 4.5Raised floor versus overhead supply
  6. 4.6Sensor placement
  7. 4.7CFD modelling of server rooms
  8. 4.8RCI and RTI indices
  9. 4.9Change management in the room
  10. 4.10Practical exercise: CFD analysis of a room with 6SigmaRoom
  1. 5.1Partial PUE and subsystem PUE
  2. 5.2WUE and water consumption
  3. 5.3CUE and carbon emissions
  4. 5.4ERF and energy reuse
  5. 5.5REF renewables indicator
  6. 5.6Continuous measurement and measurement categories
  7. 5.7Common errors in PUE calculation
  8. 5.8European Code of Conduct for Data Centre Energy Efficiency
  9. 5.9Reporting to the European database
  10. 5.10Case study: metrics audit of a data centre
  1. 6.1Raising temperature setpoints
  2. 6.2Variable speed drives on fans and pumps
  3. 6.3Differential pressure control
  4. 6.4Chiller plant optimisation
  5. 6.5Artificial intelligence in control
  6. 6.6Heat recovery for district networks
  7. 6.7IT load management and virtualisation
  8. 6.8DCIM and monitoring
  9. 6.9Predictive maintenance
  10. 6.10Workshop: PUE improvement plan
  1. 7.1Site selection and climate
  2. 7.2Modular and scalable design
  3. 7.3N+1 and 2N redundancy
  4. 7.4Strategies for high-density AI loads
  5. 7.5Water use and water stress
  6. 7.6Renewable supply and PPAs
  7. 7.7LEED and BREEAM certifications
  8. 7.8Life cycle analysis
  9. 7.9Total cost of ownership
  10. 7.10Case study: thermal design of an AI data centre
  1. 8.1Data centre characterisation
  2. 8.2PUE measurement and baseline
  3. 8.3Thermal analysis of rooms
  4. 8.4Selection of improvement measures
  5. 8.5Savings simulation
  6. 8.6Economic analysis
  7. 8.7Implementation plan and risks
  8. 8.8Metrics monitoring plan
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetable: students progress at their own pace within the intake, making it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Cadence Reality DC Design, ANSYS Fluent, EnergyPlus, Python (pandas), in free, academic or evaluation versions. Exercises are based on real CFD simulation procedures for server rooms, airflow audits and contained aisles, and on PUE and DCiE calculations using real measurements. Assessment is continuous by module, plus the final integrating project.

Accreditation-ready laboratories(EN ISO/IEC 17025) with a rotor test rig, EMC/lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-based Master's Thesis:safety case, test plan, compliance dossier and operating limits.
Industry-led mentoring:lecturers with track records in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with cyber-OT, DIH and compliance as core pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Characterisation of the data centre

Analyse the energy consumption of a data centre by subsystem.

Measurement and PUE baseline

Apply thermodynamics to cooling cycles.

Thermal analysis of rooms

Compare air, water and direct liquid cooling systems.

Selection of improvement measures

Optimise airflow with aisle containment.

Savings simulation

Calculate PUE, DCiE and complementary metrics such as WUE.

Career opportunities

Where this takes you

Data centre cooling engineerData centre energy efficiency managerCFD simulation specialistHVAC engineerData centre operations managerDigital sustainability consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

The programme uses Cadence Reality DC Design, ANSYS Fluent, EnergyPlus, Python (pandas). Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An own diploma from SEIUM upon passing the continuous assessment and the final integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area can be credited towards the advanced programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Refrigeration and Efficiency (PUE/DCiE)Enrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.