Postgraduate DiplomaElectronics, Embedded Systems & Telecom Applications open

Postgraduate Diploma in EtherCAT/Profinet/EtherNet-IP

Online Postgraduate Diploma of 800 h in EtherCAT/Profinet/EtherNet-IP. 8 modules with IEC 61158, IEC 61784-2 and Beckhoff TwinCAT 3. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
AwardSEIUM Institute diploma

Postgraduate Diploma in EtherCAT/Profinet/EtherNet-IP — studying from the United States

Electronics and telecommunications are foundational to the American economy, with research and manufacturing hubs in California, Texas, Arizona, New York and Oregon. Semiconductor investments and wireless network deployment are driving demand for hardware, firmware and systems engineers. Embedded systems now appear across automotive, medical, industrial and consumer products, requiring expertise in real-time software and secure design. Regulatory compliance with federal spectrum and safety rules is a key part of professional practice.

Fees for the United States: US$2,000 (US Dollars), with instalments and employer sponsorship available.

Relevant bodies in the United States

  • Federal Communications Commission (FCC)
  • IEEE
  • Electronic Industries Alliance (EIA)
  • Underwriters Laboratories (UL Solutions)

Typical roles

  • Embedded Systems Engineer
  • Firmware Engineer
  • RF Engineer
  • Hardware Design Engineer

Questions from the United States

Which US bodies relate to electronics, embedded systems and telecom engineering?

The IEEE is the main professional body for electronics and telecom engineers in the US, and it publishes widely used standards. The Federal Communications Commission (FCC) regulates radio and telecom equipment. Professional Engineer licensure from state boards exists but is less common in this field. SEIUM's qualifications are private and not official degrees, so recognition rests with employers or relevant bodies.

How do US electronics and telecom employers regard private online qualifications?

US semiconductor, telecom and embedded-systems employers typically look for accredited degrees, hands-on design experience and familiarity with relevant standards. A private online qualification can document focused study, but it is not a standard requirement and its value is decided by each employer. Practical design projects and certifications often carry more weight.

Can I study embedded systems from the US around a full-time role?

Yes, the programmes are online, taught in English, and do not need a student visa. The commitment is roughly 1,900 hours for a master's, 800 hours for a postgraduate diploma, or 300 hours for a specialist course. An assigned technical tutor supports your progress. Fees can be paid in instalments, and some employers fund training, so ask whether your employer offers support.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand the real-time mechanisms of industrial Ethernet.

02

Configure EtherCAT networks with distributed clocks.

03

Implement PROFINET IO networks with MRP redundancy.

04

Integrate EtherNet/IP devices using the CIP protocol.

05

Apply functional safety protocols over the bus.

06

Design network topologies suited to each application.

07

Diagnose and resolve faults in field networks.

Profile

Who it's for

  • Automation engineer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • Industrial network integrator looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • PLC programmer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • Commissioning technician looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • Motion control engineer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • Functional safety specialist looking to specialise in EtherCAT/Profinet/EtherNet-IP.
  • Graduates in engineering or sciences looking to enter manufacturing.
Standards & tools

What you'll work with

  • IEC 61158
  • IEC 61784-2
  • IEC 61784-3
  • IEC 61918
  • IEC 61784-5
  • ETG.1000
  • IEC 61508
Syllabus

8 modules · 800 h

  1. 1.1Limitations of standard Ethernet in control
  2. 1.2Real-time classes and cycle times
  3. 1.3Line, ring and star topologies
  4. 1.4Communication profiles IEC 61784-2
  5. 1.5Industrial physical layer and M12 connectors
  6. 1.6Managed industrial switches
  7. 1.7Synchronisation of distributed clocks
  8. 1.8Diagnostics and signal quality
  9. 1.9Installation per IEC 61918
  10. 1.10Practice: cycle jitter measurement
  1. 2.1On-the-fly frame processing
  2. 2.2Master and ESC slaves
  3. 2.3Addressing and datagrams
  4. 2.4PDO and FMMU mapping
  5. 2.5ESM state machine
  6. 2.6Distributed clocks and compensation
  7. 2.7ESI files and ENI configuration
  8. 2.8CoE, FoE and EoE
  9. 2.9Cable redundancy and hot connect
  10. 2.10Laboratory: configuration in TwinCAT 3
  1. 3.1Conformance classes CC-A, CC-B and CC-C
  2. 3.2RT and IRT communication
  3. 3.3Controller, device and supervisor
  4. 3.4GSDML files
  5. 3.5Naming with DCP
  6. 3.6Media redundancy MRP
  7. 3.7Diagnostics with alarms and logs
  8. 3.8PROFINET over TSN
  9. 3.9PRONETA tools and analysis
  10. 3.10Laboratory: PROFINET network in TIA Portal
  1. 4.1CIP protocol and object model
  2. 4.2Explicit and implicit messaging
  3. 4.3I/O connections and RPI
  4. 4.4EDS files
  5. 4.5Device Level Ring DLR
  6. 4.6CIP Sync and CIP Motion
  7. 4.7Integration with Logix controllers
  8. 4.8QoS and prioritisation in EtherNet/IP
  9. 4.9Connection diagnostics
  10. 4.10Laboratory: remote I/O in Studio 5000
  1. 5.1Black channel principle IEC 61784-3
  2. 5.2FSoE over EtherCAT
  3. 5.3PROFIsafe over PROFINET
  4. 5.4CIP Safety over EtherNet/IP
  5. 5.5Calculation of residual error probability
  6. 5.6Watchdogs and reaction times
  7. 5.7Parameterisation and verification of F-devices
  8. 5.8Integration with IEC 61508 and ISO 13849
  9. 5.9Validation of safety functions
  10. 5.10Case study: emergency stop on the network
  1. 6.1Topology and segment planning
  2. 6.2Cycle time and load calculation
  3. 6.3Coexistence with TCP/IP traffic
  4. 6.4Gateways between protocols
  5. 6.5Integration with OPC UA
  6. 6.6Multi-axis synchronised motion
  7. 6.7Component selection and cabling
  8. 6.8Network documentation
  9. 6.9Technical comparison of protocols
  10. 6.10Workshop: network design for a robotic cell
  1. 7.1Frame analysis with Wireshark
  2. 7.2Error counters and CRC
  3. 7.3Locating cabling faults
  4. 7.4Industrial cabling certification
  5. 7.5EMC and shielding problems
  6. 7.6Predictive network maintenance
  7. 7.7Basic cybersecurity in field networks
  8. 7.8Device firmware management
  9. 7.9Equipment replacement procedures
  10. 7.10Practice: resolution of simulated faults
  1. 8.1Control application requirements
  2. 8.2Protocol selection and justification
  3. 8.3Topology and redundancy design
  4. 8.4Device configuration
  5. 8.5Integration of safety functions
  6. 8.6Performance and diagnostic testing
  7. 8.7Final technical documentation
  8. 8.8Cost analysis
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Training 100 % online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the enrolment period, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Beckhoff TwinCAT 3, Siemens TIA Portal, Rockwell Studio 5000, Wireshark, Siemens PRONETA, in free, academic or evaluation versions. Tests are studied using real procedures for measuring cycle times and jitter, network diagnostics with a frame analyser, and validation of safety functions on the bus. Assessment is continuous per module, plus the final integrative project.

Hands-on practical workwith industry-standard software, simulation, real case studies and guided practical exercises.
Evidence-oriented final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:faculty with professional experience in the field and in real industry projects.
Flexible format(100% online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, cybersecurity and regulatory compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Control application requirements

Understand the real-time mechanisms of industrial Ethernet.

Protocol selection and justification

Configure EtherCAT networks with distributed clocks.

Topology and redundancy design

Implement PROFINET IO networks with MRP redundancy.

Device configuration

Integrate EtherNet/IP devices using the CIP protocol.

Integration of safety functions

Apply functional safety protocols over the bus.

Career opportunities

Where this takes you

Automation engineerIndustrial network integratorPLC programmerCommissioning technicianMotion control engineerFunctional safety specialist
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient English to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is between 10 and 15 hours a week on average, compatible with a full-time job.

You work with Beckhoff TwinCAT 3, Siemens TIA Portal, Rockwell Studio 5000, Wireshark and Siemens PRONETA. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

SEIUM's own diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the higher programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in EtherCAT/Profinet/EtherNet-IPEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.