Master'sHealth, Biomechanics, Wearables & Operational Safety Applications open

Master’s in Usability and Human Factors Engineering for Devices

Online master's programme of 1,900 hours in usability and human factors engineering for medical devices. 12 modules covering human error, the IEC 62366-1 framework, user research, use-related risk analysis, interface design, labelling, formative and summative evaluation, advanced measurement methods and usability across the life cycle, with an assigned technical tutor.

Duration1900 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Master’s in Usability and Human Factors Engineering for Devices — studying from the United States

Health technology and biomechanics form a significant sector in the United States, anchored by medical device hubs in Minnesota, Massachusetts, California and New Jersey. Companies develop implants, diagnostic equipment, rehabilitation devices and wearable sensors under strict regulatory oversight. Engineers apply biomechanical modeling, human factors and operational safety analysis to improve device performance and worker well-being. Careers often involve close collaboration with clinicians and regulatory affairs teams.

Fees for the United States: US$7,730 (US Dollars), with instalments and employer sponsorship available.

Relevant bodies in the United States

  • U.S. Food and Drug Administration (FDA)
  • Association for the Advancement of Medical Instrumentation (AAMI)
  • American Society of Mechanical Engineers (ASME)
  • Occupational Safety and Health Administration (OSHA)

Typical roles

  • Biomedical Engineer
  • Biomechanics Engineer
  • Wearables Development Engineer
  • Operational Safety Engineer

Questions from the United States

Which professional bodies in the United States relate to this area, and does a SEIUM qualification make me a licensed engineer?

In the US, the Professional Engineer (PE) license is issued by state licensing boards and generally requires an ABET-accredited engineering degree, supervised experience, and passing the FE and PE exams. Biomedical and safety work also connects to bodies such as ASME and IEEE EMBS. A SEIUM qualification is a private qualification, not a state degree, and does not itself grant PE licensure. Recognition is decided by employers or the relevant licensing body.

Where do people with this training typically work in the United States?

Careers in this area commonly appear in medical device companies, wearable technology firms, hospitals and research institutions, and occupational safety departments in industrial employers. Hiring decisions depend on each employer's requirements and how they value private, non-accredited training, so you should check specific job postings and speak with target employers before enrolling.

Can I study this programme while working full time in the US?

The programmes are 100% online and taught in English, so you can study from home and no student visa is needed. Master's programmes total 1,900 hours, postgraduate diplomas 800 hours, and specialist courses 300 hours, so you should plan your weekly hours realistically. Fees are payable in instalments, and some employers offer sponsorship, which you can ask your employer about directly.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Apply the IEC 62366-1 usability engineering process.

02

Research the users and use contexts of medical devices.

03

Identify critical tasks and analyse use-related risks.

04

Design interfaces, alarms and labelling that prevent errors.

05

Plan and carry out formative evaluations.

06

Validate devices through rigorous summative studies.

07

Maintain the usability engineering file throughout the life cycle.

Profile

Who it's for

  • Human factors engineers.
  • Medical device usability specialists.
  • Clinical interaction designers.
  • User experience researchers.
  • Usability regulatory consultants.
  • Use-related risk managers.
  • Engineering or science graduates looking to enter the medical device sector.
Standards & tools

What you'll work with

  • IEC 62366-1 (application of usability engineering)
  • IEC/TR 62366-2 (guidance on usability engineering)
  • Regulation (EU) 2017/745 (medical devices)
  • ANSI/AAMI HE75 (human factors engineering)
  • IEC 60601-1-6 (usability of medical electrical equipment)
  • IEC 60601-1-8 (alarm systems)
  • ISO 15223-1 (symbols for medical devices)
  • ISO 14971 (risk management)
  • Figma
  • Tobii Pro Lab
  • Morae
  • Axure RP
  • Dovetail
Syllabus

12 modules · 1900 h

  1. 1.1Human error and patient safety
  2. 1.2Reason's Swiss cheese model
  3. 1.3Error classification: slips, lapses and mistakes
  4. 1.4Use-related incidents with devices
  5. 1.5Use contexts: hospital, home and emergency
  6. 1.6Professional and lay users
  7. 1.7Cognitive load and attention
  8. 1.8Environmental factors in the clinical setting
  9. 1.9The benefit of usability engineering
  10. 1.10Case study: an infusion pump incident
  1. 2.1IEC 62366-1 engineering process
  2. 2.2IEC/TR 62366-2 application guidance
  3. 2.3MDR requirements on safe use
  4. 2.4FDA guidance Applying Human Factors (2016)
  5. 2.5AAMI HE75 human factors design
  6. 2.6IEC 60601-1-6 usability of medical electrical equipment
  7. 2.7Minimum content of the usability engineering file
  8. 2.8Interface with ISO 14971
  9. 2.9Differences between EU and FDA regulation
  10. 2.10Workshop: structure of a usability engineering file
  1. 3.1Use specification
  2. 3.2User profiles and personas
  3. 3.3Contextual observation in the clinic
  4. 3.4Interviews and focus groups
  5. 3.5Hierarchical task analysis
  6. 3.6Analysis of competitor devices
  7. 3.7Review of the MAUDE incident database
  8. 3.8Derived user requirements
  9. 3.9Needs of users with disabilities
  10. 3.10Practical exercise: task analysis of an autoinjector
  1. 4.1Hazard-related use scenarios
  2. 4.2Critical tasks and their identification
  3. 4.3PCA: perception, cognition and action
  4. 4.4Use FMEA
  5. 4.5Foreseeable errors and misuse
  6. 4.6Design, protective and information controls
  7. 4.7Prioritisation of use-related risks
  8. 4.8Link to the risk management file
  9. 4.9Reviewing the analysis after design changes
  10. 4.10Laboratory: use FMEA of a glucometer
  1. 5.1Interaction design principles
  2. 5.2Visual hierarchy and legibility
  3. 5.3Physical controls and knobs
  4. 5.4Touchscreens in clinical environments
  5. 5.5Alarm design under IEC 60601-1-8
  6. 5.6Feedback, confirmations and error prevention
  7. 5.7Iconography and ISO 15223-1 symbols
  8. 5.8Design for gloved use and sterile environments
  9. 5.9Clinical software design
  10. 5.10Practical exercise: redesigning a monitor screen
  1. 6.1MDR labelling requirements
  2. 6.2eIFU format and validation
  3. 6.3Quick reference guides and training
  4. 6.4Plain language and readability
  5. 6.5Pictograms and comprehension
  6. 6.6Labelling comprehension assessment
  7. 6.7Packaging and opening
  8. 6.8Patient labelling
  9. 6.9Translation and cultural adaptation
  10. 6.10Workshop: quick reference guide for a home-use device
  1. 7.1Objectives of formative evaluation
  2. 7.2Heuristic evaluation using Nielsen and Zhang principles
  3. 7.3Cognitive walkthroughs of critical tasks
  4. 7.4Testing with low-fidelity prototypes
  5. 7.5Testing with functional prototypes
  6. 7.6Effectiveness, efficiency and satisfaction metrics
  7. 7.7SUS scale and NASA-TLX
  8. 7.8Design iteration
  9. 7.9Formative report and redesign decisions
  10. 7.10Practical exercise: heuristic evaluation of a clinical app
  1. 8.1Planning the summative study
  2. 8.2Selection and size of user groups
  3. 8.3Representative simulated environment
  4. 8.4Prior training and training decay
  5. 8.5Critical task protocol
  6. 8.6Observation of errors and difficulties
  7. 8.7Root cause interview
  8. 8.8Analysis of results
  9. 8.9Validation report and conclusions
  10. 8.10Laboratory: simulation of a summative study
  1. 9.1Eye tracking of visual attention
  2. 9.2Physiological measures of mental workload
  3. 9.3High-fidelity clinical simulation
  4. 9.4Virtual reality for testing
  5. 9.5Video analysis and interaction logging
  6. 9.6Remote and in-home studies
  7. 9.7Mixed qualitative and quantitative methods
  8. 9.8Statistics in usability studies
  9. 9.9Ethics in user studies
  10. 9.10Case study: eye tracking in a simulated operating theatre
  1. 10.1Infusion pumps and programming errors
  2. 10.2Injection devices
  3. 10.3Ventilation equipment
  4. 10.4Monitors and central alarm stations
  5. 10.5Self-testing devices
  6. 10.6Surgical robotics consoles
  7. 10.7Software and mobile apps
  8. 10.8Drug-device combination products
  9. 10.9Devices for paediatric use and carers
  10. 10.10Case study: usability of an inhaler
  1. 11.1Integration into design control
  2. 11.2Design changes and re-evaluation
  3. 11.3Post-market use data
  4. 11.4Use-related complaints
  5. 11.5Accessibility and inclusion
  6. 11.6Management of study providers
  7. 11.7Audits of the usability file
  8. 11.8A culture of user-centred design
  9. 11.9Process effectiveness indicators
  10. 11.10Practical exercise: analysis of use-related complaints
  1. 12.1Device and use context
  2. 12.2User research
  3. 12.3Use-related risk analysis
  4. 12.4Interface design proposal
  5. 12.5Iterative formative evaluations
  6. 12.6Summative validation protocol
  7. 12.7Usability engineering file
  8. 12.8Post-market follow-up of use errors
  9. 12.9Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so the programme is compatible with full-time work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Figma, Tobii Pro Lab, Morae, Axure RP and Dovetail, in free, academic or evaluation versions. Work is based on real procedures: usability studies with users in a simulated environment, heuristic evaluations of clinical interfaces and analysis of use-related incidents in public databases. Assessment is continuous by module, plus the final Master's Thesis.

Standards covered: IEC 62366-1, IEC/TR 62366-2, Regulation (EU) 2017/745, ANSI/AAMI HE75, IEC 60601-1-6, IEC 60601-1-8, ISO 15223-1, ISO 14971.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of IEC 62366-1, IEC/TR 62366-2 and Regulation (EU) 2017/745 applied to real cases, not as a theoretical annex.
Industry software:Figma, Tobii Pro Lab, Morae, Axure RP and Dovetail, in free, academic or evaluation versions.
Master's Thesis with defence:A complete usability engineering file for a medical device, from user research to summative validation protocol, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Use context and user research
Define the device and its use context and research its users.
Use-related risk analysis
Identify critical tasks and analyse use-related risks.
Interface design and formative testing
Propose an interface design and refine it through iterative formative evaluations.
Summative validation protocol
Write the summative validation protocol and the post-market follow-up of use errors.
Master's Thesis
A complete usability engineering file for the device, defended before a panel.
Career opportunities

Where this takes you

Human factors engineerMedical device usability specialistClinical interaction designerUser experience researcherUsability regulatory consultantUse-related risk manager
Admissions & scholarships

Requirements

  • University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with Figma, Tobii Pro Lab, Morae, Axure RP and Dovetail, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Usability and Human Factors Engineering for DevicesEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.