Postgraduate Diploma in EtherCAT/Profinet/EtherNet-IP
Online Postgraduate Diploma of 800 h in EtherCAT/Profinet/EtherNet-IP. 8 modules with IEC 61158, IEC 61784-2 and Beckhoff TwinCAT 3. Assigned tutor and open enrolment.
Postgraduate Diploma in EtherCAT/Profinet/EtherNet-IP — studying from Singapore
Singapore is one of Asia's leading electronics manufacturing centres, with semiconductor fabrication, back-end assembly and test, and precision electronics concentrated in areas such as Tampines and Jurong. The sector also includes embedded systems for industrial and automotive use and a strong telecommunications base led by the Infocomm Media Development Authority. Major employers include global semiconductor firms and electronics manufacturers. Engineers work on hardware design, firmware, communications systems and test engineering.
Fees for Singapore: S$2,560 (Singapore dollar), with instalments and employer sponsorship available.
Relevant bodies in Singapore
Typical roles
Questions from Singapore
How are electronics and telecom engineers recognised in Singapore, and does SEIUM count?
Telecom and electronics engineering is regulated by the Infocomm Media Development Authority (IMDA), and engineers may register with the Professional Engineers Board (PEB). SEIUM's qualifications are private, not state degrees, and not accredited by any national body. Whether they are recognised is decided by employers or the relevant body, so confirm this before enrolling.
Which Singapore employers hire embedded systems and telecom engineers?
Singapore has demand from telecom operators, semiconductor and electronics manufacturers, defence and aerospace firms, and industrial automation companies. Employers generally assess hands-on skills in firmware, hardware design and testing. Your final project can evidence embedded or telecom competence, but its value is for each employer to judge.
Can I follow this from Singapore while working, and does it need a visa?
Yes, the programmes are 100% online and taught in English, so no student visa is needed to study from home in Singapore. Expect a heavy workload: 1,900 hours for a master's, 800 for a postgraduate diploma and 300 for a specialist course. Fees can be paid in instalments, and employer sponsorship is possible.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Understand the real-time mechanisms of industrial Ethernet.
Configure EtherCAT networks with distributed clocks.
Implement PROFINET IO networks with MRP redundancy.
Integrate EtherNet/IP devices using the CIP protocol.
Apply functional safety protocols over the bus.
Design network topologies suited to each application.
Diagnose and resolve faults in field networks.
Who it's for
- Automation engineer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- Industrial network integrator looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- PLC programmer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- Commissioning technician looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- Motion control engineer looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- Functional safety specialist looking to specialise in EtherCAT/Profinet/EtherNet-IP.
- Graduates in engineering or sciences looking to enter manufacturing.
What you'll work with
- IEC 61158
- IEC 61784-2
- IEC 61784-3
- IEC 61918
- IEC 61784-5
- ETG.1000
- IEC 61508
8 modules · 800 h
1.1Limitations of standard Ethernet in control1.2Real-time classes and cycle times1.3Line, ring and star topologies1.4Communication profiles IEC 61784-21.5Industrial physical layer and M12 connectors1.6Managed industrial switches1.7Synchronisation of distributed clocks1.8Diagnostics and signal quality1.9Installation per IEC 619181.10Practice: cycle jitter measurement
2.1On-the-fly frame processing2.2Master and ESC slaves2.3Addressing and datagrams2.4PDO and FMMU mapping2.5ESM state machine2.6Distributed clocks and compensation2.7ESI files and ENI configuration2.8CoE, FoE and EoE2.9Cable redundancy and hot connect2.10Laboratory: configuration in TwinCAT 3
3.1Conformance classes CC-A, CC-B and CC-C3.2RT and IRT communication3.3Controller, device and supervisor3.4GSDML files3.5Naming with DCP3.6Media redundancy MRP3.7Diagnostics with alarms and logs3.8PROFINET over TSN3.9PRONETA tools and analysis3.10Laboratory: PROFINET network in TIA Portal
4.1CIP protocol and object model4.2Explicit and implicit messaging4.3I/O connections and RPI4.4EDS files4.5Device Level Ring DLR4.6CIP Sync and CIP Motion4.7Integration with Logix controllers4.8QoS and prioritisation in EtherNet/IP4.9Connection diagnostics4.10Laboratory: remote I/O in Studio 5000
5.1Black channel principle IEC 61784-35.2FSoE over EtherCAT5.3PROFIsafe over PROFINET5.4CIP Safety over EtherNet/IP5.5Calculation of residual error probability5.6Watchdogs and reaction times5.7Parameterisation and verification of F-devices5.8Integration with IEC 61508 and ISO 138495.9Validation of safety functions5.10Case study: emergency stop on the network
6.1Topology and segment planning6.2Cycle time and load calculation6.3Coexistence with TCP/IP traffic6.4Gateways between protocols6.5Integration with OPC UA6.6Multi-axis synchronised motion6.7Component selection and cabling6.8Network documentation6.9Technical comparison of protocols6.10Workshop: network design for a robotic cell
7.1Frame analysis with Wireshark7.2Error counters and CRC7.3Locating cabling faults7.4Industrial cabling certification7.5EMC and shielding problems7.6Predictive network maintenance7.7Basic cybersecurity in field networks7.8Device firmware management7.9Equipment replacement procedures7.10Practice: resolution of simulated faults
8.1Control application requirements8.2Protocol selection and justification8.3Topology and redundancy design8.4Device configuration8.5Integration of safety functions8.6Performance and diagnostic testing8.7Final technical documentation8.8Cost analysis8.9Report and presentation8.10Final review with the tutor
How you'll learn
Training 100 % online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the enrolment period, which makes it possible to combine the programme with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Beckhoff TwinCAT 3, Siemens TIA Portal, Rockwell Studio 5000, Wireshark, Siemens PRONETA, in free, academic or evaluation versions. Tests are studied using real procedures for measuring cycle times and jitter, network diagnostics with a frame analyser, and validation of safety functions on the bus. Assessment is continuous per module, plus the final integrative project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Understand the real-time mechanisms of industrial Ethernet.
Configure EtherCAT networks with distributed clocks.
Implement PROFINET IO networks with MRP redundancy.
Integrate EtherNet/IP devices using the CIP protocol.
Apply functional safety protocols over the bus.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 800 hours, spread over 6 to 8 months. That is between 10 and 15 hours a week on average, compatible with a full-time job.
You work with Beckhoff TwinCAT 3, Siemens TIA Portal, Rockwell Studio 5000, Wireshark and Siemens PRONETA. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
SEIUM's own diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the higher programme. Check the credit transfer policy when you enrol.
Related programmes
Diploma in Hypervisors on ARM/x86 and I/O Virtualization
Online postgraduate diploma of 800 hours in hypervisors on ARM/x86 and I/O virtualisation. 8 modules covering virtualisation principles, ARM and x86 hardware virtualisation, I/O virtualisation, embedded…
Postgraduate Diploma in Device APIs and Versioning
800-hour online Postgraduate Diploma in Device APIs and Versioning. 8 modules covering OMA LwM2M v1.2, IETF RFC 7252 (CoAP) and Zephyr RTOS. Assigned tutor and enrolment…
Diploma in HPC Station Design and Safety
Online postgraduate diploma of 800 hours in HPC charging station design and safety. 8 modules covering high-power charging architecture, charger power electronics, vehicle-charger communication, electrical safety,…
More in Electronics, Embedded Systems & Telecom
All Electronics, Embedded Systems & Telecom programmes → · How to apply · Fees & financing · Scholarships