Master'sHealth, Biomechanics, Wearables & Operational Safety Applications open

Master’s in Prosthetics, Orthotics and Clinical Biomechanics Engineering

Online master's programme of 1,900 hours in prosthetics, orthotics and clinical biomechanics engineering. 12 modules covering clinical biomechanics, lower-limb, spinal and upper-limb orthoses, lower- and upper-limb prostheses, digital design and manufacturing, the residual limb–socket interface, functional assessment, rehabilitation and MDR regulation, with an assigned technical tutor.

Duration1900 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Master’s in Prosthetics, Orthotics and Clinical Biomechanics Engineering — studying from Singapore

Singapore's healthcare and medtech sectors are supported by the Health Sciences Authority, which regulates medical devices, and the Agency for Science, Technology and Research, which funds biomedical research. Engineers work on medical device design, biomechanics, wearable sensors and occupational safety systems. The Ministry of Manpower oversees workplace safety standards. Employers include medical device manufacturers, hospitals and research institutes in the one-north and Biopolis precincts.

Fees for Singapore: S$9,880 (Singapore dollar), with instalments and employer sponsorship available.

Relevant bodies in Singapore

  • Health Sciences Authority (HSA)
  • Ministry of Manpower (MOM)
  • Agency for Science, Technology and Research (A*STAR)
  • Biomedical Engineering Society Singapore

Typical roles

  • Medical Device Engineer
  • Biomechanics Engineer
  • Wearables Engineer
  • Occupational Safety Engineer

Questions from Singapore

Will this qualification be recognised by professional bodies in Singapore?

SEIUM's qualifications are private qualifications, not official state degrees, and they are not accredited by any national body in Singapore. Professional engineering registration in Singapore is handled through the Professional Engineers Board (PEB), which registers Professional Engineers under the Professional Engineers Act. Recognition of a private qualification is ultimately decided by employers or the relevant body, so check with them before enrolling.

How might this training be used by employers in Singapore?

Employers in Singapore's healthtech, medical device, wearables and workplace safety sectors may value specialist skills in biomechanics and operational safety. Whether they count an online private qualification toward a role is up to each employer. Many firms look at portfolios, project work and experience alongside any certificate, so the final project can be a useful piece of evidence to show them.

Can I study this alongside a full-time job, and can my employer help fund it?

The programme is 100% online and taught in English, so it suits working professionals, though the workload is significant: master's programmes are 1,900 hours, postgraduate diplomas 800 hours and specialist courses 300 hours. Fees can be paid in instalments, and employer sponsorship is possible. Many Singapore employers fund job-related training, so it is worth asking your HR or training department early.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Carry out biomechanical assessments of patients with musculoskeletal conditions.

02

Design lower-limb, upper-limb and spinal orthoses.

03

Prescribe and align lower-limb prostheses.

04

Apply myoelectric control to upper-limb prostheses.

05

Design and manufacture devices with digital technologies.

06

Assess function in users of orthoses and prostheses.

07

Meet MDR requirements for custom-made devices.

Profile

Who it's for

  • Orthotists and prosthetists looking to add engineering depth to their clinical practice.
  • Prosthetics engineers working on sockets, feet, knees or myoelectric systems.
  • Orthopaedic CAD designers moving into scanning, digital design and additive manufacturing.
  • Clinical biomechanists who assess gait and prescribe devices.
  • Amputee rehabilitation specialists who want to understand the devices their patients use.
  • R&D engineers in orthopaedic device companies.
  • Engineering or science graduates seeking to enter technical orthopaedics.
Standards & tools

What you'll work with

  • Regulation (EU) 2017/745 (EU Medical Device Regulation, MDR)
  • ISO 10328 (structural testing of lower-limb prostheses)
  • ISO 22675 (testing of ankle-foot devices)
  • ISO 13485 (quality management systems)
  • ISO 8549 (prosthetics and orthotics vocabulary)
  • ISO 14971 (risk management)
  • Order SND/44/2019 (Spanish regulation on orthoprosthetic provision)
  • Rodin4D
  • Autodesk Fusion 360
  • OpenSim
  • Abaqus
  • Meshmixer
Syllabus

12 modules · 1900 h

  1. 1.1Functional anatomy applied to orthopaedics
  2. 1.2Biomechanics of the foot-ankle complex
  3. 1.3Joint loads in the knee and hip
  4. 1.4Biomechanics of the spine
  5. 1.5Functional biomechanics of the upper limb
  6. 1.6Pathological gait deviations
  7. 1.7Clinical examination of the orthopaedic patient
  8. 1.8Functional scales in prosthetics and orthotics
  9. 1.9Baropodometry and instrumented analysis
  10. 1.10Case study: biomechanical assessment of a flat foot
  1. 2.1Custom insoles and foot orthoses
  2. 2.2Rigid and articulated ankle-foot orthoses (AFO)
  3. 2.3Knee orthoses for ligamentous instability
  4. 2.4KAFO orthoses with knee lock
  5. 2.5Hip and abduction orthoses
  6. 2.6Polypropylene and copolymer thermoplastics
  7. 2.7Three-point force systems
  8. 2.8Orthotic prescription and quality control
  9. 2.9Clinical review and device readjustments
  10. 2.10Practical: design of a polypropylene AFO
  1. 3.1Boston and Chêneau braces for scoliosis
  2. 3.2Collars and cervicothoracic orthoses
  3. 3.3Rigid and semi-rigid lumbosacral orthoses
  4. 3.4Wrist, hand and finger orthoses
  5. 3.5Dynamic orthoses with elastic tensioners
  6. 3.6Low-temperature thermoplastic splints
  7. 3.7Biomechanical correction through directed pressures
  8. 3.8Adherence to orthotic treatment
  9. 3.9Evidence on brace effectiveness
  10. 3.10Laboratory: pressure analysis in a brace
  1. 4.1Amputation levels and their biomechanics
  2. 4.2Design of PTB and TSB transtibial sockets
  3. 4.3Ischial-containment transfemoral sockets
  4. 4.4Dynamic-response prosthetic feet
  5. 4.5Polycentric and single-axis prosthetic knees
  6. 4.6Microprocessor-controlled knees
  7. 4.7Static and dynamic alignment of the assembly
  8. 4.8Osseointegration and bone-anchored prostheses
  9. 4.9Medicare K functional levels
  10. 4.10Practical: alignment of a transtibial prosthesis
  1. 5.1Upper-limb amputation levels
  2. 5.2Body-powered harness prostheses
  3. 5.3Single- and dual-channel myoelectric prostheses
  4. 5.4Commercial multi-articulating prosthetic hands
  5. 5.5EMG pattern-recognition control
  6. 5.6Targeted muscle reinnervation (TMR)
  7. 5.7Haptic and vibrotactile sensory feedback
  8. 5.8Prostheses for children
  9. 5.9Causes of prosthesis abandonment
  10. 5.10Laboratory: dual-channel myoelectric control
  1. 6.13D scanning of the residual limb and body segment
  2. 6.2CAD of sockets and orthoses with Rodin4D
  3. 6.3Powder bed fusion additive manufacturing
  4. 6.4Carbon fibre laminates and resins
  5. 6.5CNC milling of positive moulds
  6. 6.6Mass customisation in technical orthopaedics
  7. 6.7Dimensional and quality control
  8. 6.8Traceability of custom-made products
  9. 6.9Cost comparison between traditional and digital manufacturing
  10. 6.10Practical: CAD design of a transtibial socket
  1. 7.1Mechanics of residual-limb soft tissues
  2. 7.2Pressure distribution in the socket
  3. 7.3Silicone liners and suspension systems
  4. 7.4Residual-limb volume fluctuations
  5. 7.5Heat and sweating inside the socket
  6. 7.6Skin lesions and pressure ulcers
  7. 7.7Interface pressure sensors
  8. 7.8Finite element simulation of the socket
  9. 7.9Fine fitting and user comfort
  10. 7.10Case study: pressure measurement in a socket
  1. 8.1Gait analysis with prostheses
  2. 8.2Energy cost of prosthetic gait
  3. 8.3Balance and fall risk
  4. 8.4Mobility scales such as AMP and PLUS-M
  5. 8.5Quality of life in prosthetic and orthotic users
  6. 8.6Satisfaction questionnaires such as OPUS
  7. 8.7Six-minute walk and TUG functional tests
  8. 8.8Objective comparison of prosthetic components
  9. 8.9Longitudinal follow-up of the user
  10. 8.10Practical: functional assessment of a transfemoral user
  1. 9.1Pre-prosthetic phase and residual-limb care
  2. 9.2Progressive gait training
  3. 9.3Training with upper-limb prostheses
  4. 9.4Management of phantom limb pain
  5. 9.5Psychological aspects of amputation
  6. 9.6Adaptive sport and sport-specific prostheses
  7. 9.7Return to work after amputation
  8. 9.8Coordination of the rehabilitation team
  9. 9.9Remote follow-up of prosthetic and orthotic users
  10. 9.10Case study: transfemoral rehabilitation plan
  1. 10.1Custom-made devices under the MDR
  2. 10.2Statement concerning custom-made devices under Annex XIII
  3. 10.3ISO 10328 structural testing of prostheses
  4. 10.4ISO 22675 testing of prosthetic feet
  5. 10.5ISO 13485 in prosthetic and orthotic workshops
  6. 10.6Risk management for custom-made devices
  7. 10.7Common catalogue of orthoprosthetic provision of the Spanish National Health System (SNS)
  8. 10.8Professional liability of the orthotist-prosthetist
  9. 10.9Competencies and qualifications of the technician
  10. 10.10Workshop: documentation of a custom-made device
  1. 11.1Robotic ankle and knee prostheses
  2. 11.2Peripheral neural interfaces
  3. 11.3Shape-memory materials
  4. 11.4Artificial intelligence in prosthetic fitting
  5. 11.5Active orthoses with actuators
  6. 11.6Sensors embedded in sockets
  7. 11.7Ecodesign of prosthetic and orthotic components
  8. 11.8Prostheses in low-income countries
  9. 11.9Transfer of research to clinical practice
  10. 11.10Case study: low-cost 3D-printed prosthesis
  1. 12.1Selection and description of the clinical case
  2. 12.2Biomechanical assessment of the patient
  3. 12.3Reasoned prosthetic or orthotic prescription
  4. 12.4Digital design of the device
  5. 12.5Manufacture of the functional prototype
  6. 12.6Functional assessment with the user
  7. 12.7Documentation of the custom-made device
  8. 12.8Clinical follow-up plan for the user
  9. 12.9Master's Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable materials, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so the programme is compatible with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Rodin4D, Autodesk Fusion 360, OpenSim, Abaqus and Meshmixer, in free, academic or evaluation versions. Practical work is based on real procedures: design of custom orthoses and sockets, gait assessment with prostheses and structural testing of components. Assessment is continuous by module, plus the final Master's Thesis.

Standards covered: Regulation (EU) 2017/745 on medical devices, ISO 10328, ISO 22675, ISO 13485, ISO 8549, ISO 14971, Order SND/44/2019.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of the MDR, ISO 10328 and ISO 22675 applied to real cases, not as a theoretical annex.
Industry software:Rodin4D, Autodesk Fusion 360, OpenSim, Abaqus and Meshmixer, in free, academic or evaluation versions.
Master's Thesis with defence:a complete clinical case, from biomechanical assessment and prescription to digital design, prototype, functional evaluation and custom-made device documentation, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Biomechanical assessment
Assess a patient biomechanically, from clinical examination to baropodometry and gait deviations.
Orthosis and socket design
Design a polypropylene AFO and a transtibial socket in CAD with Rodin4D.
Prosthetic alignment and control
Align a transtibial prosthesis and set up dual-channel myoelectric control.
Interface and functional evaluation
Measure socket interface pressures and carry out a functional assessment of a transfemoral user.
Master's Thesis
A complete clinical case with prescription, digital design, prototype, MDR custom-made documentation and follow-up plan, defended before a panel.
Career opportunities

Where this takes you

Orthotist-prosthetistProsthetics engineerOrthopaedic CAD designerClinical biomechanistAmputee rehabilitation specialistOrthopaedic R&D engineer
Admissions & scholarships

Requirements

  • University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with Rodin4D, Autodesk Fusion 360, OpenSim, Abaqus and Meshmixer, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the software, and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Prosthetics, Orthotics and Clinical Biomechanics EngineeringEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.