Postgraduate Diploma in N-k Contingencies and Blackout Forensics
Online 800-hour Postgraduate Diploma in N-k Contingencies and Blackout Forensics. 8 modules covering Regulation (EU) 2017/1485 (system operation, SOGL), Regulation (EU) 2017/2196 (emergency and restoration, NC ER) and PSS/E. Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Explain the security criteria of the electrical system.
Carry out N-1 and N-k contingency analyses.
Model cascading failure mechanisms.
Analyse historical blackouts and their lessons.
Apply forensic methodologies to network incidents.
Design defence and restoration plans.
Incorporate resilience into network planning.
Who it's for
- Electrical system security engineer looking to specialise in N-k Contingencies and Blackout Forensics.
- Contingency analyst looking to specialise in N-k Contingencies and Blackout Forensics.
- Real-time operations engineer looking to specialise in N-k Contingencies and Blackout Forensics.
- Electrical incident investigator looking to specialise in N-k Contingencies and Blackout Forensics.
- Service restoration planner looking to specialise in N-k Contingencies and Blackout Forensics.
- Grid resilience consultant looking to specialise in N-k Contingencies and Blackout Forensics.
- Graduates in engineering or science seeking to join system operators.
What you'll work with
- Regulation (EU) 2017/1485 (system operation, SOGL)
- Regulation (EU) 2017/2196 (emergency and restoration, NC ER)
- Regulation (EU) 2019/941 (risk preparedness)
- NERC TPL-001 (transmission system planning)
- NERC EOP-005 (system restoration)
- IEC 61970 (CIM model)
8 modules · 800 h
1.1System states: normal, alert and emergency1.2N-1 criterion and its application1.3N-2 and N-k contingencies1.4Common-mode contingencies1.5Security operating procedures1.6SOGL Regulation and defence plans1.7ER Regulation on emergency and restoration1.8ENTSO-E ICS incident classification1.9System security indicators1.10Case study: security analysis of an area
2.1AC and DC load flows for contingencies2.2PTDF and LODF distribution factors2.3Contingency screening and classification2.4Double-circuit and busbar contingencies2.5Multiple contingency analysis2.6High-impact, low-probability events2.7Probabilistic risk analysis2.8PSS/E and PowerFactory tools2.9Automation with Python2.10Laboratory: N-2 screening with LODF factors
3.1Cascade propagation mechanisms3.2Successive line overloads3.3Voltage collapse3.4Loss of synchronism and separation3.5Generation tripping by protection3.6OPA and similar cascade models3.7Network theory and vulnerability3.8Self-organised criticality3.9Cascade risk indicators3.10Practice: simulation of an overload cascade
4.12003 northeast US blackout4.22003 Italian blackout4.3November 2006 European incident4.42012 India blackout4.52016 South Australia blackout4.62021 European system separation4.72025 Iberian blackout4.8Common lessons from the reports4.9Regulatory changes following the incidents4.10Case study: critical reading of the 2006 report
5.1Data sources: SCADA, PMU and recorders5.2Record synchronisation5.3Reconstruction of the sequence of events5.4Protection operation analysis5.5COMTRADE oscillography analysis5.6Incident reconstruction simulation5.7Root cause analysis5.8Human and organisational factors5.9Writing the technical report5.10Workshop: reconstruction of an incident sequence
6.1Frequency load shedding6.2Undervoltage load shedding6.3Special action schemes6.4Controlled islanding6.5Service restoration plans6.6Black start and restoration paths6.7Restoration with renewables6.8Restoration drills6.9Coordination between operators6.10Laboratory: simulation of a restoration plan
7.1Resilience to extreme events7.2Climate and weather risks7.3Cyberattacks on the electrical system7.4Resilience indicators7.5Network reinforcement planning7.6Cost-benefit assessment of security7.7Operator training with simulators7.8Situational awareness tools7.9Crisis management7.10Practice: high-impact risk matrix
8.1Definition of the system under study8.2N-1 and N-k contingency analysis8.3Identification of cascade scenarios8.4Incident simulation8.5Forensic analysis of the case8.6Evaluation of defence plans8.7Proposal of resilience measures8.8Operational recommendations8.9Report and presentation8.10Final review with the tutor
How you'll learn
Fully 100 % online study on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine study with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is PSS/E, DIgSILENT PowerFactory, PowerWorld Simulator, MATPOWER, in free, academic or evaluation versions. Cases are studied on real N-1 and N-2 contingency analysis procedures, simulation of cascading failures and reconstruction of blackout sequences. Assessment is continuous per module plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Explain the security criteria of the electrical system.
Carry out N-1 and N-k contingency analyses.
Model cascading failure mechanisms.
Analyse historical blackouts and their lessons.
Apply forensic methodologies to network incidents.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow technical regulatory texts.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 800 hours spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.
You work with PSS/E, DIgSILENT PowerFactory, PowerWorld Simulator and MATPOWER. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
A SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or diploma in the same area can be credited towards the higher programme. Check the recognition policy when enrolling.
Related programmes
Postgraduate Diploma in Resilient Planning for Extreme Climate
Online 800 h Postgraduate Diploma in Resilient Planning for Extreme Climate. 8 modules covering ISO 14090 (adaptation to climate change), ISO 14091 (vulnerability and impact assessment)…
Postgraduate Diploma in Numerical Protection and PTP Synchronisation
Online 800-hour Postgraduate Diploma in Numerical Protection and PTP Synchronisation. 8 modules covering IEEE 1588-2019 (Precision Time Protocol, PTP), IEC/IEEE 61850-9-3 (PTP profile for network automation)…
Postgraduate Diploma in DC Architectures and Bidirectional Conversion
Online 800-hour Postgraduate Diploma in DC Architectures and Bidirectional Conversion. 8 modules covering IEC 62477-1 (safety of power electronic converters), IEC 60947-2 (circuit breakers) and PLECS.…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships