Postgraduate DiplomaEnergy and Networks Applications open

Postgraduate Diploma in Electrical Architectures (UPS/STS) and Continuity

Online 800 h Postgraduate Diploma in Electrical Architectures (UPS/STS) and Continuity. 8 modules covering IEC 62040-3 (UPS system performance), IEC 62040-1 (UPS system safety) and ETAP. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the supply continuity requirements of critical loads.

02

Compare UPS topologies according to IEC 62040-3.

03

Size backup energy storage systems.

04

Explain the operation and application of STS static transfer switches.

05

Design redundant distribution architectures.

06

Carry out short-circuit, selectivity and harmonic studies.

07

Plan the operation and maintenance of critical infrastructure.

Profile

Who it's for

  • Electrical engineer in data centres who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • Critical power systems engineer who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • UPS specialist who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • Electrical operation and maintenance manager who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • Electrical studies engineer who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • Business continuity consultant who wants to specialise in Electrical Architectures (UPS/STS) and Continuity.
  • Graduates in engineering or sciences looking to enter data centres.
Standards & tools

What you'll work with

  • IEC 62040-3 (UPS system performance)
  • IEC 62040-1 (UPS system safety)
  • IEC 62310-1 (static transfer systems)
  • EN 50600 (data centre facilities)
  • ANSI/TIA-942 (data centre infrastructure)
  • IEC 60364 (low-voltage electrical installations)
  • IEEE 1100 (power and grounding of electronic equipment)
Syllabus

8 modules · 800 h

  1. 1.1Supply quality and types of disturbance
  2. 1.2Critical loads: data centres, hospitals and industry
  3. 1.3ITIC and SEMI F47 tolerance curves
  4. 1.4Uptime Institute Tier classification
  5. 1.5EN 50600 standard for data centres
  6. 1.6Availability, MTBF and MTTR
  7. 1.7Redundancy N, N+1, 2N and 2N+1
  8. 1.8Single points of failure
  9. 1.9Cost of interruption by sector
  10. 1.10Case study: criticality analysis of a hospital
  1. 2.1UPS topologies according to IEC 62040-3
  2. 2.2Double-conversion online UPS
  3. 2.3Line-interactive UPS and eco mode
  4. 2.4Modular and scalable UPS
  5. 2.5IGBT rectifiers and power factor
  6. 2.6Static and maintenance bypass
  7. 2.7Efficiency and losses by load
  8. 2.8Rotary and dynamic UPS (DRUPS)
  9. 2.9Type and routine tests
  10. 2.10Practice: UPS selection for a technical room
  1. 3.1Lead-acid VRLA batteries
  2. 3.2Lithium-ion batteries in UPS
  3. 3.3Flywheels
  4. 3.4Supercapacitors
  5. 3.5Autonomy sizing
  6. 3.6Thermal management of battery rooms
  7. 3.7Monitoring and capacity testing
  8. 3.8IEC 62485 safety standards
  9. 3.9Fire risk in lithium batteries
  10. 3.10Laboratory: autonomy calculation and ageing
  1. 4.1STS operating principle
  2. 4.2Transfer times and synchronism
  3. 4.3Transfer with and without overlap
  4. 4.4Transformer inrush currents
  5. 4.5STS on the primary and secondary side
  6. 4.6Short-circuit inhibit logic
  7. 4.7ATS versus STS equipment
  8. 4.8Dual distribution in racks and PDUs
  9. 4.9Coordination with out-of-phase sources
  10. 4.10Workshop: STS configuration for dual-feed loads
  1. 5.12N, distributed and block-redundant architectures
  2. 5.2Catcher and shared reserve
  3. 5.3Generators and their coordination with UPS
  4. 5.4Generator paralleling and synchronising busbars
  5. 5.5Medium-voltage distribution for data centres
  6. 5.6Busways and room distribution
  7. 5.7Neutral and earthing schemes
  8. 5.8Selectivity and protection discrimination
  9. 5.9380 V DC architectures
  10. 5.10Case study: comparison of architectures for a data centre
  1. 6.1IEC 60909 short-circuit studies
  2. 6.2IEEE 1584 arc flash studies
  3. 6.3Load flows under fault conditions
  4. 6.4Harmonics generated by UPS and IT loads
  5. 6.5Compatibility of generators and rectifiers
  6. 6.6IST integration testing
  7. 6.7Commissioning by levels
  8. 6.8Modelling in ETAP or PowerFactory
  9. 6.9As-built documentation
  10. 6.10Practice: selectivity study of a critical distribution
  1. 7.1Emergency operating procedures
  2. 7.2Concurrent maintenance without interruption
  3. 7.3Change management in critical systems
  4. 7.4DCIM and EPMS monitoring
  5. 7.5Root cause analysis of incidents
  6. 7.6Periodic testing under real load
  7. 7.7Human risk management
  8. 7.8Energy efficiency and PUE
  9. 7.9Maintenance contracts and SLAs
  10. 7.10Case study: analysis of an incident caused by a failed transfer
  1. 8.1Definition of loads and availability level
  2. 8.2Selection of electrical architecture
  3. 8.3Sizing of UPS and storage
  4. 8.4STS and distribution design
  5. 8.5Integration of generators
  6. 8.6Electrical studies of the solution
  7. 8.7Reliability analysis and single points of failure
  8. 8.8Test and commissioning plan
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is ETAP, SKM PowerTools, DIgSILENT PowerFactory, AutoCAD Electrical, in free, academic or evaluation versions. Tests are studied using real UPS load and transfer test procedures, selectivity and short-circuit studies, and integrated continuity tests. Assessment is continuous per module, plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with a rotor test bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:lecturers with a track record in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with cyber-OT, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Definition of loads and availability level

Analyse the supply continuity requirements of critical loads.

Selection of electrical architecture

Compare UPS topologies according to IEC 62040-3.

Sizing of UPS and storage

Size backup energy storage systems.

STS and distribution design

Explain the operation and application of STS static transfer switches.

Integration of generators

Design redundant distribution architectures.

Career opportunities

Where this takes you

Electrical engineer in data centresCritical power systems engineerUPS specialistElectrical operation and maintenance managerElectrical studies engineerBusiness continuity consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme consists of 800 hours in total, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

The programme uses ETAP, SKM PowerTools, DIgSILENT PowerFactory and AutoCAD Electrical. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM diploma awarded upon passing the continuous assessment and the integrating final project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Electrical Architectures (UPS/STS) and ContinuityEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.