Postgraduate Diploma in Digital Filtering, Artefact Detection and Signal Quality

Online 800-hour Postgraduate Diploma in Digital Filtering, Artefact Detection and Signal Quality. 8 modules covering IEC 60601-2-25 (electrocardiographs), IEC 60601-2-27 (ECG monitoring) and MATLAB (Signal Processing Toolbox). Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Describe the characteristics of the main biomedical signals.

02

Design FIR and IIR digital filters for physiological signals.

03

Apply adaptive filtering to remove interference.

04

Detect motion and electrode artefacts.

05

Calculate signal quality indices.

06

Analyse signals in the spectral and time-frequency domains.

07

Implement and validate algorithms against reference databases.

Profile

Who it's for

  • Biomedical signal processing engineer looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Monitoring algorithm developer looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Medical device software engineer looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Biomedical engineering researcher looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Health data scientist looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Algorithm validation engineer looking to specialise in Digital Filtering, Artefact Detection and Signal Quality.
  • Engineering or science graduates seeking to enter medical device manufacturers.
Standards & tools

What you'll work with

  • IEC 60601-2-25 (electrocardiographs)
  • IEC 60601-2-27 (ECG monitoring)
  • ANSI/AAMI EC57 (evaluation of arrhythmia algorithms)
  • IEC 60601-2-26 (electroencephalographs)
  • IEC 60601-2-47 (Holter systems)
  • IEC 62304
Syllabus

8 modules · 800 h

  1. 1.1Origin and characteristics of ECG, EMG, EEG and PPG
  2. 1.2Sampling and the Nyquist theorem
  3. 1.3Analogue-to-digital conversion and quantisation
  4. 1.4Signal-to-noise ratio
  5. 1.5Noise sources in acquisition
  6. 1.6Mains interference and harmonics
  7. 1.7Baseline drift
  8. 1.8Wearable versus clinical signals
  9. 1.9Data formats: EDF and WFDB
  10. 1.10Practice: exploring PhysioNet recordings
  1. 2.1Discrete systems and the Z-transform
  2. 2.2Frequency and phase response
  3. 2.3FIR filters: windows and optimal design
  4. 2.4IIR filters: Butterworth, Chebyshev and elliptic
  5. 2.5Zero-phase filtering
  6. 2.6Notch filters
  7. 2.7Stability and numerical precision
  8. 2.8Real-time implementation
  9. 2.9Design with SciPy and MATLAB
  10. 2.10Laboratory: designing ECG filters in Python
  1. 3.1Adaptive LMS and RLS filters
  2. 3.2Noise cancellation with a reference
  3. 3.3Kalman filter
  4. 3.4Median and non-linear filters
  5. 3.5Wavelet transform and thresholding
  6. 3.6Empirical mode decomposition
  7. 3.7Independent component analysis
  8. 3.8Spatial filtering in multichannel recordings
  9. 3.9Comparison of noise removal methods
  10. 3.10Practice: motion artefact cancellation in PPG
  1. 4.1Artefact types: motion, contact and saturation
  2. 4.2Physiological artefacts: ocular and muscular
  3. 4.3Threshold-based detection
  4. 4.4Statistical indicators: kurtosis and entropy
  5. 4.5Machine learning detection
  6. 4.6Use of accelerometers as reference
  7. 4.7Marking and segmentation
  8. 4.8Interpolation and reconstruction
  9. 4.9Validation against expert annotations
  10. 4.10Laboratory: EEG artefact detector
  1. 5.1Concept of the signal quality index (SQI)
  2. 5.2SQI for ECG: kSQI, bSQI and pSQI
  3. 5.3SQI for PPG: perfusion and morphology
  4. 5.4Quality in EEG and EMG
  5. 5.5Fusion of quality indices
  6. 5.6Acceptable or unacceptable classification
  7. 5.7Real-time quality in devices
  8. 5.8Impact of quality on clinical accuracy
  9. 5.9Labelled quality databases
  10. 5.10Practice: calculating SQI on ambulatory ECG recordings
  1. 6.1Discrete Fourier transform and FFT
  2. 6.2Power spectral density: Welch's method
  3. 6.3Spectral leakage and windows
  4. 6.4Spectrograms and STFT
  5. 6.5Continuous wavelet analysis
  6. 6.6Frequency-domain heart rate variability analysis
  7. 6.7EEG bands
  8. 6.8Median frequency in EMG and fatigue
  9. 6.9Coherence between signals
  10. 6.10Laboratory: spectral analysis of HRV
  1. 7.1Filtering on microcontrollers
  2. 7.2Fixed-point arithmetic
  3. 7.3Latency and group delay
  4. 7.4Edge versus cloud processing
  5. 7.5IEC 60601-2-47 and 2-27 requirements
  6. 7.6Algorithm verification
  7. 7.7Reference test sets
  8. 7.8Documentation for medical software
  9. 7.9Continuous improvement with field data
  10. 7.10Case study: validating an ECG pipeline on a patch
  1. 8.1Signal and application selection
  2. 8.2Noise characterisation
  3. 8.3Filter design
  4. 8.4Artefact detection
  5. 8.5Quality index
  6. 8.6Pipeline implementation
  7. 8.7Performance evaluation
  8. 8.8Technical documentation
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine study with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is MATLAB (Signal Processing Toolbox), Python (SciPy, MNE), PhysioNet WFDB, EEGLAB, in free, academic or trial versions. Tests are studied using real processing procedures on PhysioNet databases, recording signals with controlled artefacts, and validating algorithms against reference annotations. Assessment is continuous per module plus the final integrative project.

Accredited laboratories(EN ISO/IEC 17025) with rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:faculty with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, OT cybersecurity, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Signal and application selection

Describe the characteristics of the main biomedical signals.

Noise characterisation

Design FIR and IIR digital filters for physiological signals.

Filter design

Apply adaptive filtering to remove interference.

Artefact detection

Detect motion and electrode artefacts.

Quality index

Calculate signal quality indices.

Career opportunities

Where this takes you

Biomedical signal processing engineerMonitoring algorithm developerMedical device software engineerBiomedical engineering researcherHealth data scientistAlgorithm validation engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient level of Spanish to follow the reading of technical regulations.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

You work with MATLAB (Signal Processing Toolbox), Python (SciPy, MNE), PhysioNet WFDB, EEGLAB. Free, academic or trial versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official Ministry qualification.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in Digital Filtering, Artefact Detection and Signal QualityEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.