Postgraduate Diploma in AMI Architectures and Interoperability
Online 800-hour Postgraduate Diploma in AMI Architectures and Interoperability. 8 modules covering IEC 62056 (DLMS/COSEM), ITU-T G.9904 (PRIME) and Wireshark. Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Describe the components of an advanced metering infrastructure.
Compare field communication technologies such as PRIME and G3-PLC.
Apply the DLMS/COSEM data model.
Assess interoperability between devices and systems.
Define cybersecurity and privacy protection measures.
Manage the operation of the smart metering system.
Design advanced applications based on AMI data.
Who it's for
- AMI systems architect looking to specialise in AMI Architectures and Interoperability.
- PLC communications engineer looking to specialise in AMI Architectures and Interoperability.
- Interoperability specialist looking to specialise in AMI Architectures and Interoperability.
- Metering cybersecurity engineer looking to specialise in AMI Architectures and Interoperability.
- Smart metering operations manager looking to specialise in AMI Architectures and Interoperability.
- Smart grid consultant looking to specialise in AMI Architectures and Interoperability.
- Graduates in engineering or sciences seeking to join electricity distribution companies.
What you'll work with
- IEC 62056 (DLMS/COSEM)
- ITU-T G.9904 (PRIME)
- ITU-T G.9903 (G3-PLC)
- IEC 61968-9 (meter reading and control)
- IEC 62443 (industrial cybersecurity)
- Recommendation 2012/148/EU (smart meter deployment)
- Regulation (EU) 2016/679 (GDPR)
8 modules · 800 h
1.1Components of an AMI system1.2Meters, concentrators and head-end1.3Smart metering deployment in Spain1.4Directive 2019/944 and smart meters1.5Minimum functionalities recommended by the EU1.6Distribution and retail use cases1.7Benefits and cost-benefit analysis1.8Evolution towards second-generation meters1.9International deployment comparison1.10Case study: AMI architecture of a distribution company
2.1Narrowband PLC: PRIME and G3-PLC2.2RF mesh radio networks2.3Cellular communications: NB-IoT and LTE-M2.4LoRaWAN for metering2.5Topologies and coverage2.6Noise on the low-voltage network2.7Repeaters and link quality2.8Communications network planning2.9Reading and success indicators2.10Laboratory: PRIME frame analysis
3.1DLMS/COSEM and IEC 620563.2OBIS object model3.3Company profiles and STOD3.4SML protocol and alternatives3.5CIM model IEC 61968-93.6Head-end and MDM interfaces3.7Messaging and web services3.8Semantic interoperability3.9Firmware versioning and compatibility3.10Practice: decoding COSEM objects
4.1GWAC interoperability levels4.2EU Mandate M/4414.3Conformance and interoperability testing4.4PRIME, G3 and DLMS UA alliances4.5Consumer interfaces (HAN)4.6P1 ports and domestic devices4.7Multi-vendor interoperability4.8Standard lifecycle management4.9Interoperability challenges with IoT4.10Workshop: interoperability test plan
5.1Threats to AMI infrastructure5.2DLMS security: suites and keys5.3Key management and PKI5.4Secure firmware and remote updates5.5Data concentrator security5.6Data protection and GDPR5.7Privacy impact assessment5.8Security certification schemes5.9AMI incident response5.10Case study: risk analysis of a concentrator
6.1Meter inventory management6.2Mass firmware updates6.3Alarm and event management6.4Remote disconnection and reconnection6.5Network performance monitoring6.6Maintenance and replacement6.7Quality of service indicators6.8Integration with GIS and OMS6.9Supplier management6.10Practice: AMI performance dashboard
7.1Low-voltage topology detection7.2Transformer monitoring7.3Outage management with last gasp alarms7.4Flexibility and demand response7.5Self-consumption and energy communities7.6Electric vehicle integration7.7Consumption analytics for customers7.8Data for network planning7.9Data platforms and energy data spaces7.10Laboratory: phase identification using meter data
8.1Definition of requirements and use cases8.2Selection of communication technologies8.3System architecture design8.4Interoperability strategy8.5Cybersecurity plan8.6Deployment plan8.7Cost-benefit analysis8.8Monitoring indicators8.9Report and presentation8.10Final review with the tutor
How you'll learn
Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the enrolment period, which makes it easy to combine with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Wireshark, Gurux DLMS, Python, SAP IS-U, in free, academic or evaluation versions. Tests are studied using real procedures for meter interoperability testing, communication frame analysis and AMI cybersecurity assessments. Assessment is continuous per module plus the final integrative project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Describe the components of an advanced metering infrastructure.
Compare field communication technologies such as PRIME and G3-PLC.
Apply the DLMS/COSEM data model.
Assess interoperability between devices and systems.
Define cybersecurity and privacy protection measures.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme’s software.
- Spanish language proficiency sufficient to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme comprises 800 hours in total, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.
You will work with Wireshark, Gurux DLMS, Python, SAP IS-U. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
An own diploma from SEIUM upon passing the continuous assessment and the final integrative project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit transfer policy when enrolling.
Related programmes
Postgraduate Diploma in Eligibility, Taxonomy and ESG Reporting
Online 800-hour postgraduate diploma in Eligibility, Taxonomy and ESG Reporting. 8 modules covering Regulation (EU) 2020/852 (taxonomy), Delegated Regulation (EU) 2021/2139 (climate delegated act) and advanced…
Postgraduate Diploma in Island Operation and Black Start
Online 800-hour Postgraduate Diploma in Island Operation and Black Start. 8 modules covering Regulation (EU) 2017/2196 (Network Code on Emergency and Restoration), Regulation (EU) 2016/631 (RfG…
Postgraduate Diploma in State Estimation and Losses
Online 800-hour Postgraduate Diploma in State Estimation and Losses. 8 modules with IEC 61970 (CIM model for energy management systems), IEEE C37.118.1 (synchrophasors) and MATLAB. Assigned…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships