Master’s in High Power for HPC/UPS and Fast Charging: Redundancy
Online master's programme of 1,900 hours in high power for HPC/UPS and fast charging — redundancy, cooling and reliability. 12 modules covering availability and reliability, redundant topologies, infrastructure classification, quantitative reliability analysis, UPS and fast-charging redundancy, protection and selectivity, mechanical and thermal redundancy, commissioning, operation and maintenance, and resilience and business continuity, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Quantify the reliability and availability of electrical systems.
Design redundant topologies suited to each need.
Apply Tier and EN 50600 classifications.
Analyse reliability with fault trees and Markov models.
Ensure redundancy in UPS, charging and cooling.
Plan commissioning tests and concurrent operation.
Develop resilience and business continuity plans.
Who it's for
- Electrical reliability engineers.
- Critical facilities design engineers.
- Data centre operations managers.
- Commissioning engineers.
- Business continuity consultants.
- Protection engineers.
- Engineering or science graduates looking to move into data centres.
What you'll work with
- EN 50600-2-2 (data centre power distribution)
- ANSI/TIA-942 (data centre telecommunications infrastructure)
- IEC 61078 (reliability block diagrams)
- IEC 61025 (fault tree analysis)
- IEC 62040-3 (UPS performance and test requirements)
- ISO 22301 (business continuity management)
- Directive (EU) 2022/2555 (NIS2 — cybersecurity)
- Regulation (EU) 2023/1804 (AFIR — alternative fuels infrastructure)
- ETAP
- ReliaSoft BlockSim
- Isograph Reliability Workbench
- EcoStruxure Power
- MATLAB
12 modules
1.1Reliability, availability and maintainability concepts1.2MTBF, MTTR and availability1.3Nines of availability1.4Single points of failure1.5The cost of downtime1.6Critical loads in HPC and charging1.7Electrical failure modes1.8Component reliability1.9Reliability databases1.10Case study: cost of an outage in an HPC centre
2.1N, N+1 and 2N redundancy2.22N+1 redundancy2.3Distributed redundant systems2.4Catcher redundancy2.5Block redundant2.6Dual-corded equipment2.7Static transfer switches (STS)2.8Cost-availability comparison2.9Common design errors2.10Lab: comparison of topologies using block diagrams
3.1Uptime Institute Tiers3.2Concurrent maintainability3.3Fault tolerance3.4EN 50600 and availability classes3.5ANSI/TIA-9423.6Design certification3.7Facility certification3.8Operational sustainability3.9Compliance audits3.10Practical: Tier assessment of a design
4.1Reliability block diagrams4.2Fault trees4.3Markov chains4.4Repair models4.5Monte Carlo simulation4.6Common-cause failures4.7Importance analysis4.8ReliaSoft tools4.9Validation with field data4.10Lab: fault tree of a 2N system
5.1Redundant parallel UPS5.2Hot-swap modules5.3String-based batteries5.4Rectifier redundancy5.5Bypass and maintenance5.6Source synchronisation5.7UPS control failures5.8Redundancy testing5.9Discharge tests5.10Practical: maintenance strategy without shutdown
6.1Redundant power modules6.2Dynamic power sharing6.3Graceful degradation6.4Charging hubs with storage6.5Dual grid connection6.6Availability required by AFIR6.7Remote charger supervision6.8Predictive maintenance of chargers6.9Uptime indicators6.10Case study: design of a hub with 99% availability
7.1Protection coordination7.2Total and partial selectivity7.3Differential protection7.4Breaker failure7.5Internal arcing and its containment7.6Protection of transfers7.7Studies with ETAP7.8Protection testing7.9Settings documentation7.10Lab: selectivity study
8.1N+1 cooling8.2Redundant pumps and chillers8.3Ring water loops8.4Thermal storage8.5Cooling failure and response time8.6Redundant HPC liquid cooling8.7Redundant controls8.8Electrical-mechanical interdependencies8.9Failure testing8.10Practical: failure analysis of a chiller
9.1Commissioning levels9.2Factory acceptance tests9.3Integrated systems testing9.4Grid failure tests9.5Load banks9.6Pull-the-plug tests9.7Test documentation9.8Issue management9.9Client acceptance9.10Workshop: IST test script
10.1MOP, SOP and EOP procedures10.2Concurrent maintenance10.3Change management10.4Operator training10.5Human error and its prevention10.6Monitoring and alarms10.7Incident analysis10.8Operational indicators10.9Spare parts management10.10Case study: root cause analysis of an outage
11.1External and climate risks11.2Cybersecurity of electrical systems11.3ISO 22301 business continuity11.4NIS2 Directive11.5Resilience of critical entities11.6Emergency plans11.7Geographic redundancy11.8Insurance and risk11.9Drills11.10Practical: continuity plan for a charging centre
12.1Availability requirements12.2Proposed topology12.3Reliability analysis12.4Protection design12.5Thermal redundancy12.6Test plan12.7Operating procedures12.8Cost-availability analysis12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
100% online learning on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within the intake, so you can combine it with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is ETAP, ReliaSoft BlockSim, Isograph Reliability Workbench, EcoStruxure Power and MATLAB, in free, academic or evaluation versions. Testing is studied through real procedures: integrated systems testing, load bank tests and grid failure drills. Assessment is continuous by module, plus the final Master's Thesis.
Standards covered: EN 50600-2-2, ANSI/TIA-942, IEC 61078, IEC 61025, IEC 62040-3, ISO 22301, Directive (EU) 2022/2555 (NIS2), Regulation (EU) 2023/1804 (AFIR).
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- Internet connection and a computer able to run the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with ETAP, ReliaSoft BlockSim, Isograph Reliability Workbench, EcoStruxure Power and MATLAB, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Aerospace Compliance Engineering
Online master's programme of 1,900 hours in aeronautical compliance engineering, structured in 12 modules covering the regulatory framework, ARP4754B system development, ARP4761A safety assessment, DO-178C software,…
Master’s in User Satcom
Online master's programme of 1,900 hours in user satcom — terminals, modems, pointing and Ka/Ku-band links. 12 modules covering satellite communication systems, propagation and link budgets,…
Master’s in Power Electronics Engineering (Specialisation)
Online master's programme of 1,900 hours in power electronics engineering: 12 modules covering Si, SiC and GaN semiconductors, isolated and non-isolated DC-DC converters, inverters, PFC, control,…
More in Electronics, Embedded Systems & Telecom
All Electronics, Embedded Systems & Telecom programmes → · How to apply · Fees & financing · Scholarships