Diploma in Qualification/Validation and PQ
Online postgraduate diploma of 800 hours in qualification/validation and PQ: 8 modules covering qualification fundamentals, IQ, OQ, PQ, process validation, statistical tools and maintenance of the qualified state under EudraLex Volume 4 Annex 15, the FDA Process Validation Guidance 2011 and ASTM E2500-20, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Plan equipment qualification according to Annex 15 and ASTM E2500.
Write IQ protocols with verifiable acceptance criteria.
Design and run OQ tests of functions and limits.
Plan a representative PQ with statistical criteria.
Apply the three-stage approach to process validation.
Analyse qualification data using statistical tools.
Maintain the qualified state through change control and requalification.
Who it's for
- Qualification and validation technicians.
- Process validation engineers.
- Validation managers.
- Thermal mapping specialists.
- Pharmaceutical commissioning engineers.
- GMP quality auditors.
- Engineering or science graduates seeking to move into the pharmaceutical industry.
What you'll work with
- EudraLex Volume 4 Annex 15 (qualification and validation)
- FDA Process Validation Guidance 2011 (lifecycle approach to process validation)
- ASTM E2500-20 (science- and risk-based verification of manufacturing systems)
- ICH Q8(R2) (pharmaceutical development)
- ICH Q9(R1) (quality risk management)
- EudraLex Volume 4 Annex 1 (manufacture of sterile medicinal products)
- ISPE Baseline Guide Commissioning and Qualification (C&Q practice)
- WHO TRS 1019 Annex 3 (validation guidelines)
- Kneat Gx
- ValGenesis VLMS
- Minitab
- JMP
- Ellab ValSuite
8 modules
1.1Difference between qualification and validation1.2The Annex 15 lifecycle approach1.3User requirements as the starting point1.4Design qualification (DQ)1.5Verification according to ASTM E25001.6Factory and site acceptance testing1.7Leveraging FAT and SAT1.8Roles of quality, engineering and users1.9Qualification documentation1.10Case study: qualification strategy for a filling machine
2.1Objectives of IQ2.2Verification of drawings and documentation2.3Checking materials and certificates2.4Instrumentation and calibrations2.5Verification of software and versions2.6Connected utilities2.7Deviations during IQ2.8Installation acceptance criteria2.9IQ report2.10Practical exercise: IQ protocol for an autoclave
3.1Objectives of OQ3.2Function and alarm testing3.3Operating limit testing3.4Interlock and safety testing3.5Control system testing3.6Thermal mapping of equipment3.7Power failure recovery testing3.8OQ deviation management3.9OQ report3.10Workshop: OQ testing of a freeze dryer
4.1Objectives and scope of PQ4.2Use of product or placebo4.3Design of PQ batches4.4Worst cases and extreme conditions4.5Sampling and statistical plans4.6Statistical acceptance criteria4.7Process capability in PQ4.8Sterility assurance in PQ4.9PQ report and approval4.10Practical exercise: PQ sampling plan for a tablet line
5.1The 2011 FDA process validation guidance5.2Stage 1: process design5.3Stage 2: process performance qualification5.4Stage 3: continued process verification5.5Number of validation batches5.6Concurrent and retrospective validation5.7Aseptic process validation with media fill5.8Transport validation5.9Revalidation and changes5.10Case study: PPQ protocol for a granulation process
6.1Design of experiments for the process6.2Tolerance intervals6.3Cpk and Ppk capability6.4Control charts for continued verification6.5Analysis of variance between batches6.6Justified sample size6.7Equivalence testing6.8Statistical software6.9Interpretation for inspectors6.10Laboratory: capability analysis of PQ data
7.1Calibration and preventive maintenance7.2Periodic requalification7.3Change control and impact assessment7.4Annual product review7.5Trending of critical parameters7.6Management of recurring deviations7.7Paperless qualification7.8Qualification audits7.9Lessons learned7.10Practical exercise: risk-based requalification plan
8.1Selection of the equipment and process8.2User requirements8.3DQ, IQ and OQ strategy8.4PQ design8.5Statistical sampling plan8.6Process validation protocol8.7Continued verification plan8.8Evaluation of results8.9Report and presentation8.10Final project: final review with the tutor
How you'll learn
Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, making it compatible with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Kneat Gx, ValGenesis VLMS, Minitab, JMP and Ellab ValSuite, in free, academic or evaluation versions. Tests are studied on real procedures: an IQ/OQ qualification protocol for a piece of equipment, statistical design of a PQ, and thermal mapping of an autoclave. Assessment is continuous by module plus the final project.
Standards covered: EudraLex Volume 4 Annex 15, FDA Process Validation Guidance 2011, ASTM E2500-20, ICH Q8(R2), ICH Q9(R1), EudraLex Volume 4 Annex 1, ISPE Baseline Guide Commissioning and Qualification, WHO TRS 1019 Annex 3.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 800 hours over 6–8 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with Kneat Gx, ValGenesis VLMS, Minitab, JMP and Ellab ValSuite, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.
Prior technical training or professional experience in the sector (no university degree required), a computer capable of running the software, and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Postgraduate Diploma in Impedance/Admittance and Controlled Contact
Online Postgraduate Diploma of 800 h in Impedance/Admittance and Controlled Contact. 8 modules covering ISO/TS 15066:2016, ISO 10218-1:2025 and ROS 2 with ros2_control. Assigned tutor and…
Postgraduate Diploma in V&V and Configuration Management
Online 800-hour Postgraduate Diploma in V&V and Configuration Management. 8 modules with IEEE 1012-2016, ISO/IEC/IEEE 15288:2023 and Git. Assigned tutor and enrolment open.
Diploma in Life Cycle Cost and Reliability
Online postgraduate diploma of 800 hours in life cycle cost and reliability. 8 modules covering IEC 60300-3-3:2017, IEC 61703:2016 and ISO 15663:2021, with ReliaSoft Weibull++ and…
More in Robotics, Automation & Control
All Robotics, Automation & Control programmes → · How to apply · Fees & financing · Scholarships