Master'sElectromobility, Batteries & Hydrogen Applications open

Master’s in Battery Thermal Management and Safety

Online master's programme of 1,900 hours in battery thermal management and safety — thermal CFD, thermal runaway propagation and intumescent materials. 12 modules covering cell thermal behaviour, thermal modelling, cooling and heating systems, pack CFD, thermal runaway, propagation and mitigation, abuse testing, functional safety and BMS, regulations and type approval, and life-cycle safety, with an assigned technical tutor.

Duration12–14 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Master’s in Battery Thermal Management and Safety — studying from Canada

Canada is building capacity in electric vehicles, battery manufacturing and hydrogen technologies, supported by federal and provincial investment. Ontario's automotive corridor is attracting battery cell and materials projects, while Québec and British Columbia have strong hydro-powered grids and clean technology clusters. Hydrogen research and fuel cell development are active in Alberta, Ontario and British Columbia. Engineers work on battery systems, charging infrastructure, power electronics and energy storage, with employers including automakers, cell manufacturers and utilities.

Fees for Canada: C$10,800 (Canadian dollar), with instalments and employer sponsorship available.

Relevant bodies in Canada

  • Natural Resources Canada (NRCan)
  • Canadian Standards Association (CSA Group)
  • Electric Mobility Canada
  • Hydrogen Business Council

Typical roles

  • Battery Engineer
  • Electrification Engineer
  • Power Electronics Engineer
  • Hydrogen Systems Engineer

Questions from Canada

Which Canadian bodies regulate electromobility or battery engineering titles?

In Canada, the title Professional Engineer is regulated by provincial associations such as Professional Engineers Ontario, which require accredited education and supervised experience. SEIUM is a private institute, and its qualifications are not official state degrees or accredited by a national body, so they do not confer P.Eng. status. Employers or relevant bodies decide recognition, so check with them directly.

Is there demand in Canada for battery, hydrogen and electrification skills?

Canada has growing activity in electric vehicles, battery manufacturing and hydrogen, with projects in Ontario, Quebec, Alberta and British Columbia. Employers generally assess candidates on technical skills, project evidence and experience. A SEIUM final project can demonstrate your competence, but how a private qualification is viewed rests with each employer, so ask them before committing.

Can I study this while working, and what level of English is required?

Yes, the programmes are 100% online, so you can study from home without a student visa and schedule around your job. Specialist courses are 300 hours, postgraduate diplomas 800 and master's 1,900. Instruction is in English, so you should be comfortable with technical English. Instalments and possible employer sponsorship can help with costs.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse heat generation and transfer in cells.

02

Model the electrothermal behaviour of cells and packs.

03

Design battery cooling and heating systems.

04

Understand the mechanisms of thermal runaway.

05

Design measures to mitigate propagation.

06

Plan abuse and safety tests.

07

Apply battery safety regulations.

Profile

Who it's for

  • Battery thermal management engineers.
  • Battery safety engineers.
  • CFD engineers.
  • Abuse testing engineers.
  • Functional safety engineers.
  • Battery type-approval engineers.
  • Engineering or science graduates looking to move into electric automotive.
Standards & tools

What you'll work with

  • UNECE Regulation No. 100 (electric powertrain safety)
  • UN GTR No. 20 (electric vehicle safety)
  • UN 38.3 (lithium battery transport testing)
  • IEC 62619 (safety of industrial lithium batteries)
  • UL 9540A (thermal runaway fire propagation testing)
  • Regulation (EU) 2023/1542 (EU Batteries Regulation)
  • ISO 6469-1 (on-board rechargeable energy storage safety)
  • ISO 26262 (road vehicle functional safety)
  • Ansys Fluent
  • Simcenter STAR-CCM+
  • COMSOL Multiphysics
  • MATLAB Simulink
  • GT-SUITE
Syllabus

12 modules

  1. 1.1Reversible and irreversible heat generation
  2. 1.2Entropy and heat of reaction
  3. 1.3Anisotropic thermal conductivity
  4. 1.4Specific heat of cells
  5. 1.5Optimal operating temperatures
  6. 1.6Effect of temperature on service life
  7. 1.7Thermal gradients within the cell
  8. 1.8Cell calorimetry
  9. 1.9Comparison by format
  10. 1.10Case study: thermal balance of a cell under fast charging
  1. 2.1Lumped-parameter models
  2. 2.2Coupled electrothermal models
  3. 2.33D finite element models
  4. 2.4Electrochemical-thermal models
  5. 2.5Thermal resistance networks
  6. 2.6Parameter identification
  7. 2.7Reduced-order models for the BMS
  8. 2.8Validation with thermocouples
  9. 2.9Simulation tools
  10. 2.10Lab: electrothermal model in Simulink
  1. 3.1Air cooling
  2. 3.2Liquid cooling with cold plates
  3. 3.3Immersion cooling
  4. 3.4Phase change materials
  5. 3.5Thermal interface materials (TIM)
  6. 3.6Cooling channel design
  7. 3.7Pressure drop and pumping
  8. 3.8Integration with the vehicle circuit
  9. 3.9Comparison of solutions
  10. 3.10Practical: cold plate design
  1. 4.1Low-temperature performance
  2. 4.2Lithium plating during cold charging
  3. 4.3PTC heaters
  4. 4.4Integrated heat pumps
  5. 4.5Cell self-heating
  6. 4.6Preconditioning
  7. 4.7Operation in hot climates
  8. 4.8Management while parked
  9. 4.9Thermal energy consumption
  10. 4.10Lab: preheating strategy
  1. 5.1Pack meshing
  2. 5.2Flow in plates and manifolds
  3. 5.3Conjugate heat transfer
  4. 5.4Temperature uniformity
  5. 5.5Fast-charging simulation
  6. 5.6Drive cycles
  7. 5.7Design optimisation
  8. 5.8Reduced-order models
  9. 5.9Correlation with tests
  10. 5.10Practical: CFD of a liquid-cooled module
  1. 6.1Thermal runaway mechanisms
  2. 6.2Temperature-driven exothermic reactions
  3. 6.3SEI and electrolyte decomposition
  4. 6.4Internal short circuit
  5. 6.5Vent gases and their composition
  6. 6.6ARC calorimetry
  7. 6.7Influence of chemistry
  8. 6.8Abuse test data
  9. 6.9Thermal runaway modelling
  10. 6.10Lab: interpretation of ARC tests
  1. 7.1Cell-to-cell propagation
  2. 7.2Thermal barriers and materials
  3. 7.3Spacing and module design
  4. 7.4Vent gas management
  5. 7.5Valves and exhaust channels
  6. 7.6Early detection
  7. 7.7Escape time requirements
  8. 7.8Propagation tests
  9. 7.9Design for safety
  10. 7.10Practical: design of barriers between cells
  1. 8.1Overcharge and overdischarge
  2. 8.2External short circuit
  3. 8.3Nail penetration
  4. 8.4Crush
  5. 8.5Fire exposure
  6. 8.6Water immersion
  7. 8.7Vibration and mechanical shock
  8. 8.8Thermal cycling
  9. 8.9Laboratories and protocols
  10. 8.10Case study: abuse test plan
  1. 9.1BMS safety functions
  2. 9.2Temperature monitoring
  3. 9.3Sensor placement
  4. 9.4Thermal anomaly detection
  5. 9.5Disconnection and contactors
  6. 9.6ISO 26262 applied to batteries
  7. 9.7HARA analysis
  8. 9.8Fault diagnosis
  9. 9.9Safety during charging
  10. 9.10Lab: thermal diagnostic strategy
  1. 10.1UNECE Regulation 100
  2. 10.2GTR 20 on EV safety
  3. 10.3UN 38.3 for transport
  4. 10.4IEC 62619 for stationary batteries
  5. 10.5UL 9540A
  6. 10.6Regulation (EU) 2023/1542
  7. 10.7China's GB 38031 requirements
  8. 10.8Technical documentation
  9. 10.9Testing bodies
  10. 10.10Workshop: regulatory compliance matrix
  1. 11.1Manufacturing and quality control
  2. 11.2Battery transport
  3. 11.3Safe storage
  4. 11.4Fire brigade response
  5. 11.5Rescue in accidents
  6. 11.6Second life and safety
  7. 11.7Recycling and dismantling
  8. 11.8Fires in car parks
  9. 11.9Lessons from incidents
  10. 11.10Case study: EV fire response protocol
  1. 12.1Thermal and safety requirements
  2. 12.2Cell thermal model
  3. 12.3Cooling concept
  4. 12.4Pack simulation
  5. 12.5Thermal runaway analysis
  6. 12.6Mitigation measures
  7. 12.7Test plan
  8. 12.8Regulatory compliance
  9. 12.9Master's Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

100% online learning on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within the intake, so you can combine it with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Ansys Fluent, Simcenter STAR-CCM+, COMSOL Multiphysics, MATLAB Simulink and GT-SUITE, in free, academic or evaluation versions. Testing is studied through real procedures: ARC calorimetry of cells, thermal runaway propagation tests and thermal testing of packs in a climatic chamber. Assessment is continuous by module, plus the final Master's Thesis.

Standards covered: UNECE Regulation No. 100, UN GTR No. 20, UN 38.3, IEC 62619, UL 9540A, Regulation (EU) 2023/1542 (batteries), ISO 6469-1, ISO 26262.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of UNECE Regulation No. 100, UN GTR No. 20 and UN 38.3 applied to real cases, not as a theoretical annex.
Industry software:Ansys Fluent, Simcenter STAR-CCM+, COMSOL Multiphysics, MATLAB Simulink and GT-SUITE, in free, academic or evaluation versions.
Master's Thesis with defence:a complete battery thermal and safety design, from the cell thermal model to mitigation, test plan and regulatory compliance, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Requirements and cell model
Define thermal and safety requirements and build the cell thermal model.
Cooling concept and pack simulation
Design the cooling concept and simulate the pack with CFD.
Thermal runaway analysis
Analyse thermal runaway and its propagation through the pack.
Mitigation and test plan
Specify mitigation measures and the abuse and safety test plan.
Master's Thesis
A complete thermal and safety design with its regulatory compliance, defended before a panel.
Career opportunities

Where this takes you

Battery thermal management engineerBattery safety engineerCFD engineerAbuse testing engineerFunctional safety engineerBattery type-approval engineer
Admissions & scholarships

Requirements

  • University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • Internet connection and a computer able to run the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with Ansys Fluent, Simcenter STAR-CCM+, COMSOL Multiphysics, MATLAB Simulink and GT-SUITE, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Battery Thermal Management and SafetyEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.