Master’s in Energy for Data Centres

Online master's programme of 1,900 hours in energy for data centres — UPS/STS, cooling, PUE and continuity. 12 modules covering data centres and energy consumption, power supply and grid connection, UPS systems, backup generation, white-space power distribution, air and liquid cooling, energy efficiency and metrics, renewables and decarbonisation, heat and water recovery, and operation, monitoring and regulation, with EN 50600-2-2, ISO/IEC 30134-2 and Directive (EU) 2023/1791 and an assigned technical tutor.

Duration12–14 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma

Master’s in Energy for Data Centres — studying from Australia

Australia's energy sector is undergoing major transition, with significant growth in renewable generation, grid-scale storage and transmission upgrades. The National Electricity Market and the Wholesale Electricity Market in Western Australia are key frameworks shaping investment and operations. Engineers work on network planning, power system analysis, asset management and integration of distributed energy resources. Employers include network operators, generators, retailers, the Australian Energy Market Operator and engineering consultancies.

Fees for Australia: A$11,000 (AUD), with instalments and employer sponsorship available.

Relevant bodies in Australia

  • Australian Energy Regulator (AER)
  • Australian Energy Market Operator (AEMO)
  • Clean Energy Regulator
  • Energy Networks Australia

Typical roles

  • Power Systems Engineer
  • Network Planning Engineer
  • Grid Integration Engineer
  • Energy Asset Engineer

Questions from Australia

Which Australian bodies and regulators cover energy and networks engineering?

Engineers Australia is the main professional body, and the Australian Energy Regulator and the Australian Energy Market Operator oversee the national electricity market. State network regulators also apply. SEIUM's private qualifications are not accredited by these bodies, so recognition is decided by employers or the regulator.

What energy and network careers in Australia could this training support?

Australia has electricity network operators, renewable energy developers, grid planners and utilities that employ engineers in these fields. Employers usually prioritise accredited qualifications, licensing and project experience. A SEIUM qualification may add to your profile, but its value depends on each employer.

Is the course workable with a job, and does employer funding exist?

Yes, the programmes are online and taught in English, so you can study from Australia without a student visa. Specialist courses are 300 hours, diplomas 800 and master's 1,900, with an assigned technical tutor and final project. Fees are payable in instalments, and employer sponsorship may be possible, though it is arranged case by case.

Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Design the power supply of data centres according to their availability level.

02

Size UPS systems and backup generation.

03

Design air and liquid cooling systems.

04

Calculate and optimise efficiency metrics such as PUE.

05

Integrate renewables and decarbonisation strategies.

06

Assess waste heat recovery.

07

Apply EN 50600 and European reporting obligations.

Profile

Who it's for

  • Data centre infrastructure engineers.
  • Mission-critical electrical engineers.
  • Cooling engineers.
  • Energy and sustainability managers.
  • Data centre operations managers.
  • Energy efficiency consultants.
  • Engineering or science graduates seeking to enter the data centre sector.
Standards & tools

What you'll work with

  • EN 50600-2-2 (data centre facilities — power supply and distribution)
  • ISO/IEC 30134-2 (power usage effectiveness, PUE)
  • Directive (EU) 2023/1791 (Energy Efficiency Directive)
  • Delegated Regulation (EU) 2024/1364 (EU data centre rating and reporting scheme)
  • ANSI/TIA-942 (telecommunications infrastructure standard for data centres)
  • ISO 50001 (energy management systems)
  • ASHRAE TC 9.9 Thermal Guidelines (environmental envelopes for IT equipment)
  • EN 50600-4-2 (power usage effectiveness KPI)
  • 6SigmaDCX
  • Schneider EcoStruxure IT
  • ETAP
  • Sunbird DCIM
  • EnergyPlus
Syllabus

12 modules

  1. 1.1Typologies: hyperscale, colocation and edge
  2. 1.2Components of the physical infrastructure
  3. 1.3Evolution of power density per rack
  4. 1.4Impact of artificial intelligence on demand
  5. 1.5Global electricity consumption of data centres
  6. 1.6Availability levels Tier I to IV
  7. 1.7Life cycle of a data centre
  8. 1.8PUE, WUE and CUE indicators
  9. 1.9Stakeholders and business models
  10. 1.10Case study: energy profile of a 50 MW campus
  1. 2.1High- and medium-voltage connections
  2. 2.2On-campus substations
  3. 2.3Grid access capacity and permitting
  4. 2.42N, N+1 and distributed architectures
  5. 2.5Transformers and main switchboards
  6. 2.6Required quality of supply
  7. 2.7Supply contracts and network tariffs
  8. 2.8Flexibility towards the grid
  9. 2.9Phased expansion planning
  10. 2.10Practical exercise: single-line diagram of a Tier III facility
  1. 3.1Double-conversion UPS topologies
  2. 3.2Modular and scalable UPS
  3. 3.3VRLA versus lithium-ion batteries
  4. 3.4Autonomy and sizing
  5. 3.5Efficiency in eco mode
  6. 3.6Maintenance of UPS systems
  7. 3.7Coordination with generator sets
  8. 3.8Transfer tests
  9. 3.9Battery system monitoring
  10. 3.10Lab: sizing a UPS and batteries
  1. 4.1Diesel generator sets
  2. 4.2HVO and alternative fuels
  3. 4.3Fuel storage
  4. 4.4Fuel cells as backup
  5. 4.5Batteries as a replacement for generators
  6. 4.6Emissions and environmental permits
  7. 4.7Periodic load testing
  8. 4.8Synchronisation and paralleling of generators
  9. 4.9Start-up reliability
  10. 4.10Practical exercise: diesel-free backup strategy
  1. 5.1Power distribution units (PDUs)
  2. 5.2Busways and busbar trunking
  3. 5.3400 V and 48 V DC distribution
  4. 5.4Selectivity and protection
  5. 5.5Per-rack metering
  6. 5.6Phase balancing
  7. 5.7Arc flash in technical rooms
  8. 5.8Earthing of IT equipment
  9. 5.9Compatibility with AI racks
  10. 5.10Lab: per-rack metering and load balancing
  1. 6.1Heat load of IT equipment
  2. 6.2ASHRAE environmental ranges
  3. 6.3Hot and cold aisles
  4. 6.4Aisle containment
  5. 6.5CRAC and CRAH units
  6. 6.6Direct and indirect free cooling
  7. 6.7Chillers and cooling towers
  8. 6.8CFD simulation of data halls
  9. 6.9Humidity control
  10. 6.10Practical exercise: CFD model of a data hall
  1. 7.1Limits of air for high density
  2. 7.2Direct-to-chip cooling
  3. 7.3Single-phase and two-phase immersion
  4. 7.4Rear-door heat exchangers
  5. 7.5Coolant distribution units
  6. 7.6Fluid quality and materials
  7. 7.7Elevated water temperatures
  8. 7.8Integration with existing systems
  9. 7.9Risks and maintenance
  10. 7.10Case study: data hall for GPU clusters
  1. 8.1Detailed PUE calculation
  2. 8.2ISO/IEC 30134 series metrics
  3. 8.3Metering and sub-metering
  4. 8.4Set-point optimisation
  5. 8.5Variable-speed drives in pumps and fans
  6. 8.6Server efficiency
  7. 8.7Virtualisation and consolidation
  8. 8.8Compute workload management
  9. 8.9Efficiency reporting to the EU
  10. 8.10Lab: PUE analysis with hourly data
  1. 9.1Renewable PPAs
  2. 9.2Guarantees of origin
  3. 9.324/7 carbon-free energy
  4. 9.4On-campus self-consumption
  5. 9.5Battery storage
  6. 9.6Scope 1, 2 and 3 carbon footprint
  7. 9.7Embodied carbon in construction
  8. 9.8Climate neutrality targets
  9. 9.9The Climate Neutral Data Centre Pact
  10. 9.10Practical exercise: 24/7 carbon-free supply strategy
  1. 10.1Waste heat from data centres
  2. 10.2Heat pumps for upgrading heat
  3. 10.3Integration with district heating networks
  4. 10.4Water use in cooling
  5. 10.5Reducing WUE
  6. 10.6Reclaimed water and alternatives
  7. 10.7The Energy Efficiency Directive
  8. 10.8Business models for heat
  9. 10.9Nordic reference cases
  10. 10.10Workshop: feasibility of selling heat to a district network
  1. 11.1DCIM management platforms
  2. 11.2Capacity management
  3. 11.3Predictive maintenance of infrastructure
  4. 11.4Incident and change management
  5. 11.5The EN 50600 series
  6. 11.6Uptime Institute certifications
  7. 11.7EU delegated reporting regulation
  8. 11.8Cybersecurity of management systems
  9. 11.9Energy management to ISO 50001
  10. 11.10Case study: energy audit of a data centre
  1. 12.1Definition of the data centre
  2. 12.2Availability and density requirements
  3. 12.3Power supply design
  4. 12.4Cooling design
  5. 12.5Efficiency strategy
  6. 12.6Decarbonisation plan
  7. 12.7Economic evaluation of the facility
  8. 12.8Sustainability indicators
  9. 12.9Master's Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so you can combine the programme with your job.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is 6SigmaDCX, Schneider EcoStruxure IT, ETAP, Sunbird DCIM and EnergyPlus, in free, academic or evaluation versions. Practical work is based on real procedures for integrated systems testing during commissioning, CFD simulation of data halls and energy efficiency audits. Assessment is continuous for each module, plus the final Master's Thesis.

Standards covered: EN 50600-2-2, ISO/IEC 30134-2, Directive (EU) 2023/1791 on energy efficiency, Delegated Regulation (EU) 2024/1364, ANSI/TIA-942, ISO 50001, ASHRAE TC 9.9 Thermal Guidelines and EN 50600-4-2.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of EN 50600, ISO/IEC 30134-2 and the Energy Efficiency Directive applied to real cases, not as a theoretical annex.
Industry software:6SigmaDCX, Schneider EcoStruxure IT, ETAP, Sunbird DCIM and EnergyPlus, in free, academic or evaluation versions.
Master's Thesis with defence:The energy design of a complete data centre, from availability requirements and power supply to cooling, efficiency strategy, decarbonisation plan and economic evaluation, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Facility definition
Define the data centre, its availability tier and power density requirements.
Power supply design
Design the grid connection, UPS, backup generation and distribution.
Cooling design
Select and size air or liquid cooling, validated with CFD.
Efficiency and decarbonisation
Set the PUE strategy, renewable supply and heat recovery plan.
Master's Thesis
Present the complete design with its economic evaluation, defended before a panel.
Career opportunities

Where this takes you

Data centre infrastructure engineerMission-critical electrical engineerCooling engineerEnergy and sustainability managerData centre operations managerEnergy efficiency consultant
Admissions & scholarships

Requirements

  • University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with 6SigmaDCX, Schneider EcoStruxure IT, ETAP, Sunbird DCIM and EnergyPlus, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Energy for Data CentresEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.