Diploma in Electromagnetic Compatibility (EMC) in Defence
Online postgraduate diploma of 800 hours in electromagnetic compatibility (EMC) in defence, structured in 8 modules covering interference principles, MIL-STD-461G testing, MIL-STD-464 system requirements, design for compatibility, EMC instrumentation, electromagnetic simulation and civil and military standards such as DEF STAN 59-411, with an assigned technical tutor.
Diploma in Electromagnetic Compatibility (EMC) in Defence — studying from Australia
Defence is one of Australia's largest engineering employers, with major programmes in land systems, naval platforms, aircraft and integrated systems managed through the Department of Defence. Land systems engineering supports armoured vehicles, weapons and logistics equipment, often through prime contractors and local industry partners. Industry involvement is strongly encouraged through the Defence industry policy framework. Engineers work on sustainment, capability development, systems integration and safety assurance, typically in Canberra, Adelaide, Melbourne and regional defence precincts.
Fees for Australia: A$2,380 (AUD), with instalments and employer sponsorship available.
Relevant bodies in Australia
Typical roles
Questions from Australia
How does defence engineering recognition work in Australia?
Defence engineering in Australia is largely run through the Department of Defence and its industry partners, which set their own security clearance and qualification requirements. Engineers Australia is the professional body for accreditation. SEIUM's private qualifications are not accredited by these bodies, so recognition is for employers or the relevant body to decide.
Which Australian employers hire in defence and land systems?
Australia has defence prime contractors, the Department of Defence, and specialist land systems firms. Many of these roles require Australian security clearances, which depend on citizenship and background checks rather than course completion. Ask employers how they weigh private qualifications against experience and clearance requirements.
Is the course manageable with a job, and does it need a visa?
The programmes are 100% online and taught in English, so you can study from Australia without a student visa. Specialist courses take 300 hours, diplomas 800 and master's 1,900. An assigned technical tutor supports you, fees are payable in instalments, and employer sponsorship may be possible.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Understand electromagnetic coupling mechanisms.
Perform and interpret MIL-STD-461G tests.
Apply the system requirements of MIL-STD-464.
Design equipment using compatibility criteria.
Use EMC instrumentation and estimate measurement uncertainty.
Simulate coupling and shielding problems.
Compare civil and military compatibility requirements.
Who it's for
- EMC engineers working on defence equipment.
- Compatibility laboratory technicians.
- Defence electronics designers.
- Systems integration engineers.
- Electromagnetic simulation specialists.
- Certification engineers.
- Engineering or science graduates looking to enter the defence sector.
What you'll work with
- MIL-STD-461G (EMI control requirements for subsystems and equipment)
- MIL-STD-464D (electromagnetic environmental effects requirements for systems)
- DEF STAN 59-411 (UK MoD electromagnetic compatibility standard)
- AECTP-500 (NATO electromagnetic environmental effects test procedures)
- RTCA DO-160G (environmental conditions and test procedures for airborne equipment)
- Directive 2014/30/EU (EU electromagnetic compatibility directive)
- CISPR 16-1-1 (radio disturbance measuring apparatus)
- IEC 61000-4-2 (electrostatic discharge immunity testing)
- CST Studio Suite
- Ansys HFSS
- Keysight PathWave ADS
- R&S EMC32
- MATLAB
8 modules
1.1Sources of interference1.2Conducted and radiated coupling1.3Inductive and capacitive coupling1.4Common mode and differential mode1.5Spectrum of digital signals1.6Source and load impedance1.7Near field and far field1.8Units in dBµV and dBµA1.9Intra-system and inter-system compatibility1.10Practical exercise: spectrum of a trapezoidal signal
2.1Conducted emissions CE101 and CE1022.2Conducted susceptibility CS101 and CS1142.3CS115, CS116 and CS118 tests2.4Radiated emissions RE101 and RE1022.5Radiated susceptibility RS101 and RS1032.6General test set-up2.7Line impedance stabilisation networks2.8Tailoring of limits2.9Test reports2.10Laboratory: CE102 pre-compliance
3.1Safety margins3.2External electromagnetic environment3.3Direct and indirect effects of lightning3.4Electromagnetic pulse3.5Electrostatic discharge3.6Radiation hazards to personnel and fuel3.7Electrical continuity and bonding3.8Compatibility between subsystems3.9Platform testing3.10Case study: EMI control plan for a platform
4.1Printed circuit board design4.2Ground planes and return paths4.3Line filters4.4Shielding and conductive gaskets4.5Cables and connectors4.6System grounding4.7Transient suppressors4.8Enclosure shielding4.9Switch-mode power supplies4.10Workshop: design of an input filter
5.1EMI receivers5.2Spectrum analysers5.3Measurement antennas5.4Current probes5.5Anechoic, GTEM and reverberation chambers5.6Calibration of the measurement chain5.7Uncertainty to CISPR 16-4-25.8Test automation5.9Laboratory accreditation5.10Practical exercise: uncertainty of an RE102 measurement
6.1Method of moments6.2FDTD and TLM6.3Finite elements6.4Cable harness simulation6.5Shielding effectiveness6.6Antenna-to-antenna coupling6.7Component models6.8Validation against measurements6.9Platform-level simulation6.10Laboratory: coupling in a cable harness
7.1Directive 2014/30/EU7.2Harmonised standards EN 55032 and EN 550357.3EMC sections of DO-160G7.4British standard DEF STAN 59-4117.5NATO AECTP-500 procedures7.6ESD immunity to IEC 61000-4-27.7Specific naval requirements7.8COTS equipment on military platforms7.9Qualification strategies7.10Case study: civil and military test matrix
8.1Description of the equipment or system8.2Expected electromagnetic environment8.3Applicable requirements and limits8.4EMC risk analysis8.5Design measures8.6Supporting simulations8.7Test plan8.8Margin analysis8.9Report and presentation8.10Final project: final review with the tutor
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so the programme can be combined with your job.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is CST Studio Suite, Ansys HFSS, Keysight PathWave ADS, R&S EMC32 and MATLAB, in free, academic or evaluation versions. Testing is studied through real procedures for emissions and susceptibility tests in an anechoic chamber, shielding effectiveness measurements and platform-level EMC tests. Assessment is continuous by module, plus the final project.
Standards covered: MIL-STD-461G, MIL-STD-464D, DEF STAN 59-411, AECTP-500, RTCA DO-160G, Directive 2014/30/EU, CISPR 16-1-1, IEC 61000-4-2.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 800 hours over 6–8 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with CST Studio Suite, Ansys HFSS, Keysight PathWave ADS, R&S EMC32 and MATLAB, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.
Prior technical training or professional experience in the sector (no university degree required), a computer able to run the programme software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Diploma in UXO Detection Technologies
Online postgraduate diploma of 800 hours in UXO detection technologies. 8 modules covering explosive remnants of war, non-technical survey and information management, electromagnetic detection, ground-penetrating radar,…
Diploma in UGV and Autonomous Land Platforms
Online postgraduate diploma of 800 hours in UGV and autonomous land platforms. 8 modules covering unmanned ground platforms, perception sensors, localisation and mapping, motion planning and…
Diploma in FADEC Control Systems and Safety
Online postgraduate diploma of 800 hours in FADEC Control Systems and Safety. 8 modules covering gas turbines and their control, control laws, FADEC architecture, system safety…
More in Defense, Military Engineering & Land Systems
All Defense, Military Engineering & Land Systems programmes → · How to apply · Fees & financing · Scholarships